BTL7-A-CB02-...
Calibration box
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The calibration box is used to set the null and end points
of the BTL transducer.
Opening the calibration box or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup of the transducer may only be
performed by trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
Technical data
Supply voltage range
Current draw (without transducer)
Voltage measuring channel characteristics
–
Measuring range
–
Resolution
–
Accuracy
Current measuring channel characteristics
–
Measuring range
–
Resolution
–
Accuracy
Degree of protection per IEC 60529
Operating temperature range
Wiring safety
Overvoltage protection
Inverse-polarity protection
Startup
DANGER
Uncontrolled system movement
► The system must be taken out of operation before
making adjustments.
► Transducers may only be connected to the
calibration box for setting purposes.
► The calibration box must be removed after setting is
complete.
1
english
Construction and function
The calibration box facilitates setting the null and end
points of transducers equipped with an analog interface.
One major advantage is that the measured output can be
verified in real time using the LCD display on the calibration
box.
10...30 V
Max. 50 mA
–11...+11 V
10 bit
±30 mV
0...23 mA
Examples:
10 bit
–
±50 µA
–
IP40
0...+50°C
Yes
36 V
–36 V
Downloading further instructions
A complete user's guide for the respective transducer can
be downloaded from the Internet at www.balluff.com or
requested via e-mail from service@balluff.de.
4
1
2
1
Button 1 (programming input La)
2
Button 2 (programming input Lb)
3
Selects the transducer output to be measured
4
8-pin socket
5
6-pin socket
BTL6-A/C/E/G500-M_ _ _ _-PF-S115
BTL7-A/C/E/G-M_ _ _ _-_-S32/S115/cable
(not for BTL7 USB-configurable)
For special versions of the ...-SA _ _ _, the
connection assignment may deviate.
The transducer must have high-active
programming inputs.
The calibration procedure is described in the
transducer user's guide.
3
5