• After the start of charging, the voltage of
the DC output for battery charging has
exceeded the specified level (17.5 V).
• The battery voltage did not rise to the
specified level within a specified period
(2 hours).
The charging indicators remain flashing
until the a side of the POWER switch is
pressed, the AC power cord is disconnected,
or the battery pack is removed.
Notes
• When a battery pack that is not
chargeable with the BC-L70 is
connected, charging does not take place.
• The BP-M50/M100 Nickel Metal
Hydride Battery Packs cannot be charged
with the BC-L70.

Specifications

General
Voltage source
100–240V AC,
50/60 Hz
Current drain
168 VA or less
Peak inrush current (1) Power ON, current
probe method: 15 A
(100 V)/35 A (240 V)
(2) Hot switching
inrush current,
measured in
accordance with
European standard
EN55103-1: 12 A
(230 V)
Operating temperature
0°C to 45°C
(32°F to 113°F)
Mass
Approx. 1.2 kg
(2 lb 10 oz)
Dimensions (w/h/d) 134 × 237 × 60 mm
(5
inches) (excluding
projecting parts)
Input/output
Current input (AC) 140 VA 1.4 A at
maximum
Power output (DC) 100 W at maximum
Voltage output (DC) 16.8 V
Current output (DC) 6 A at maximum
DC output connector
XLR-type 4-pin
connector
16.7 V
Battery charging connector (DC)
Square-shaped 5-pin
connector
16.8 V, 5 A/3 A
3
× 9
3
× 2
3
/
/
/
8
8
8
Specifications