Skil 0805 Manual Original página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
• Only use an extension cord of
type H05RN-F which is intended
for outdoor use and equipped
with a watertight plug and
coupling-socket
• Only use extension cords with
a maximum length of 40 metres
(1,0 mm²), 60 metres (1,5 mm²)
or 100 metres (2,5 mm²)
• Use completely unrolled and
safe extension cords with a
capacity of 16 Amps (U.K. 13
Amps)
• Inspect the extension cord
periodically and replace it,
if damaged (inadequate
extension cords can be
dangerous)
• Protect the (extension) cord from
heat, oil and sharp edges
• If the power cable is damaged,
send the pump to a SKIL
service station (addresses are
listed on www.skil.com)
• Immediately disconnect the
plug if the (extension) cord is
damaged
EXPLANATION OF SYMBOLS
ON TOOL
3 Do not dispose of the tool
together with household waste
material
4 Maximum operating depth
USE
Assembly 5
- screw connection elbow A/hose connector B into
pump outlet
- connect a 25 mm (1") hose to hose connector B
- to allow other hose diameters, cut off the nipples of the
universal hose connector as illustrated
- for optimal results use a hose with a diameter of 32
mm (1 1/4") and with a length as short as possible (be
aware that after switching off remaining water in the
hose will increase the residual water depth)
- when using a 32 mm (1 1/4") or a 25 mm (1") hose, we
recommend to fasten it with an additional hose clamp
Operating the appliance 6
- place the pump on a firm surface in the water to be
transferred (or use a rope attached to carrying handle
C to immerse the pump in a well or shaft)
! ensure that float switch D can move freely
- air may escape through air bleed valve E and air
bubbles may appear underwater
- it may take several seconds for the air to escape when
the pump is immersed for the first time
- wait until the air bubbles have disappeared
- plug power cable F into a mains socket
! connect this earthed appliance only to a properly
earthed power supply system; ensure that socket
and extension cable have a functional protective
conductor
Automatic mode 6
- float switch D automatically turns on the pump when
the water level exceeds the switch-on height
- float switch D turns off the pump again when the water
level drops below the switch-off height
Adjusting switch-ON and switch-OFF height 6
- push float switch cable G into cable holder H
- the shorter the length of the cable between float switch
D and cable holder H, the lower the switch-ON height
and the higher the switch-OFF height
! ensure that the cable length between float switch
D and cable holder H is at least 10 cm
Manual mode 7
- switch on the pump manually by raising float switch D
- be aware that water level must be above 30-40 mm
(0805) / 70-80 mm (0810) to ensure that the pump
can draw in water
- fix/hold float switch D vertically above the pump
! as long as the float switch is positioned vertically
above the pump, the pump will continue to
operate regardless of the water level
- the minimal residual water depth (approx. 5 mm 0805
/ 35 mm 0810) can only be achieved in manual mode,
because the float switch already switches off the pump
in an earlier stage when in automatic mode
- observe the pump at all times during manual mode
! immediately unplug the pump when it stops
drawing in water (avoid dry-running operation)
Thermal protection
- the built-in thermal protection switches off the motor in
the event of overheating
- after a cooling-down phase of approximately 15-30
minutes, the pump switches on automatically
MAINTENANCE / SERVICE
This tool is not intended for professional use
If the appliance should fail despite the care taken in
manufacturing and testing procedures, repair should
be carried out by an after-sales service centre for SKIL
power tools
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0810

Tabla de contenido