LCD Programmable Thermostat
Code: 0769006, Reference: KT6-LCD
A.
Installation, Mounting:
CAUTION:
1. Turn off 0769006, electronic source and the electrical devices (e.g. heater, cooler)
which will be connected before installation and maintenance.
2. The installer must be a trained service engineer.
1. Installation Location:
The thermostat should be mounted on an inner wall 1.5m above the floor in position
where it is readily affected by changes of the general room temperature with freely
circulating air. Prevent direct exposure to sunlight; dripping or splashing area. Do not
place this unit at a location where air circulation is low, or where it has great
temperature changes (e.g. near door). Do not place the thermostat near heat/cool
generating sources (radiators, hot air vents, TV or lights).
2. Wiring:
There are 3 wiring terminals at the bottom of 0769006, labeled as "COM"(Common),
"C"(Cooler), "H" (Heater). Connect a heater to "H" terminal and connect a cooler to
the "C" terminals. Leaves unused hole blank.
Wire the correct cables to the terminal block according to the circuit diagram which is
attached inside the thermostat top cover.
Push all cables back into wall prior to fixing to avoid trapping wires.
It is recommended that the wiring connection to the supply is via a fuse rated at no
more than 5 Amps. (Please refer to the wiring diagram on the last page.)
3. Mounting:
Using the accessory screws and wall anchors provided, mount 0769006 with the
key-hole at the back. The thermostat should be mounted on the wall as shown in step
3 of Figure1. Install the cover on 0769006 as shown in step 4 of Figure1.
Install or replace the battery:
Caution: Turn off the electrical devices and disconnect the supply to the appliances
before replacing the batteries. Replace only with the same or equivalent type of
batteries. Do not dispose the used batteries with household waste. Refer to your
local area for the proper disposal.
1. Pull out the battery drawer
2. Place the new batteries according to the marking on the battery drawer.
3. Dispose the old batteries properly.
4. Slide the battery drawer back to its position.
5. Check if the thermostat works properly or not.
Press "RST" if necessary.
Use a flat screwdriver
to press on the gap at
both sides to detach
the front shell.
B.
Start/Reset:
1. After wiring and mounting, switch off all the connected devices. Place 2 new AAA
1.5V alkaline batteries according to the polarities marked.
LCD display will be switched on.
2. Slide the switch at the position ("
" /
") which matches with the control device
(heater/ cooler).
3. Press 'RST' to reset. The 0769006 will be ready to control the heater / cooler.
4. Switch ON the heater / cooler. The heater / cooler will remain OFF
until 0769006 activates the output ON with
C.
Normal Time Mode:
1. Temperature detection starts and LCD displays the room temperature.
2. If Battery is LOW,
immediately.
-P
3. Defrost function is activated with
will be forced to ON @ Heat & OFF @ Cool.
4. Below 0°C, 0769006 will display LO.
5. Above 40°C, 0769006 will display HI.
D. Normal Time Setting Mode:
1. Press <
>, the Day of Week (1-7) will flash, press < >, < > to select the current Day
of Week.
2. Press <
>, the Hour will flash, press < >, < > to set the Hour.
3. Press <
>, the Minute will flash, press < >, < > to set the Minute.
4. Press <
> will jump back to the step 1.
5. Press <
> to confirm the settings and return to Normal Mode.
Or 0769006 will auto-return to normal mode after 10 seconds.
E. Factory Defined Programs:
The heater / cooler turns on according to the activated program and the control temperature
setting. When the heater / cooler is On, Program number and
The pre-defined programs are as below:
Heater mode:
P1
P2
P3
P4
Cooler mode:
P1
P2
P3
P4
F. Set Program:
1. Press <PRG>, the hour will flash, press < >, < > to change the hour setting.
2. Press <PRG>, the minutes will flash, press < >, < > to change the minutes setting.
3. Press <PRG>, temperature will flash, press < >, < > to change the setpoint.
4. Press <PRG> to set the next program.
5. The program setting sequence is as below:
Mon~Fri (P1 P2 P3 P4) Sat (P1 P2 P3 P4)
Sun (P1 P2 P3 P4)...
6. Press <
> to exit the program mode setting and return to the normal mode.
Or 0769006 will auto-return to normal mode after 10 seconds.
G. Temporary / Permanent Override Mode:
There are two modes in the override mode (Temporary override and Permanent override
mode). Press
The sequence is as below:
Normal Temporary Override Permanent Override Normal...
Selecting the Temporary/ Permanent Override Mode
<
> to
1. Press
displayed.
Figure 1
<
>
2. Press
mode.
icon will be displayed.
<
>
3. Press
Review and adjust the Override temperature:
1. Press < >/< >, the Override temperature is shown.
2. Hold the < >/< > for 2 seconds, the Override temperature will flash.
3. Press < >/< > to adjust the Override temperature.
4. Press <
> to exit the Override temperature setting.
Or 0769006 will auto-return to normal mode after 10 seconds.
/
displayed on LCD.
will be flashing. The old batteries must be replaced with new one
displayed when temperature is 5°C or below. Output
/
Mon ~ Fri
Sat
06:00 (21°C)
08:00 (21°C)
08:00 (21°C)
08:00 (16°C)
10:00 (16°C)
10:00 (16°C)
18:00 (21°C)
18:00 (21°C)
18:00 (21°C)
22:00 (16°C)
23:00 (16°C)
23:00 (16°C)
Mon ~ Fri
Sat
06:00 (24.0°C)
08:00 (24.0°C)
08:00 (24.0°C)
08:00 (29.5°C)
10:00 (29.5°C)
10:00 (29.5°C)
18:00 (29.5°C)
18:00 (29.5°C)
18:00 (29.5°C)
22:00 (26.0°C)
23:00 (26.0°C)
23:00 (26.0°C)
<
>
to select the override mode.
change the mode from normal to Temporary Override.
again, the mode changes from Temporary Override to Permanent Override
once, the mode changes from Permanent Override to normal mode.
Temporary Override Mode:
Temporary override Mode maintains until next program time is met.
Permanent Override Mode:
The room temperature will be maintained at the override temperature until
override mode is released. Press <
mode.
H. Control Off / Sleep Mode:
1. Press the <
> to select the sleep mode and control off mode. The sequence is
as below:
Normal Mode Sleep Mode Control Off ModeNormal Mode ...
2. Press any other keys to exit the control off / Sleep mode and return normal
mode.
Sleep Mode:
At sleep mode, <
displaying the temperature. Only the current time is shown.
The heater / cooler is turned off, irrespective of the current control setting
temperature.
Control Off Mode:
The LCD is fully turned off. The heater / cooler is switched off, irrespective of
the current control temperature setting.
icons are shown.
I. Slide Switch Selection
-
When the slide switch is set at "
Sun
The thermostat controls the heater "ON" or "OFF" only.
-
When the slide switch is set at "
selected. The thermostat controls the cooler "ON" or "OFF" only.
J. Jumper Selection:
Delay / No Delay jumper:
Heater
No delay
10sec
Sun
Delay
4mins
Choose the Delay option if compressor heat is connected.
12-hours / 24-hours mode jumper:
When the 12-hours option is selected, the time is shown in 12-hours mode.
Otherwise, the time is shown in 24-hours mode.
K. Specification:
1. Temperature measurement: 0.0 - 40°C (0.1°C/step)
2. Accuracy:
3. Temperature control range:
4. Switching:
5. Terminals:
6. Electronic control:
7. Battery:
8. Operating temperature:
9. Storage temperature:
10. Sensing element:
Terminal block Connecting Label:
icon will be
TEMPER ENERGY INTERNATIONAL S.L.
Polígono industrial de Granda, nave 18
33199 • Granda - Siero • Asturias
Teléfono: (+34) 902 201 292
Fax: (+34) 902 201 303
Email: info@grupotemper.com
www.grupotemper.com
> to release the Permanent override
> icon is displayed. 0769006 stops measuring and
" position, the heater option is selected.
" position, the cooler option is
Cooler
4mins
4mins
± 0.5°C
5.0 - 35.0°C (0.5°C/step)
24..250VAC 50/60Hz 5(1)A max
2
2.5mm
cable
Type 2.B action
2 x 1.5V AAA alkaline battery
0 - 50°C
0 - 50°C
NTC thermistor