I Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
Cooling Model
COOL / DRY Operation
FAN Operation
AUTO
AUTO
36°
61°
Swing up/down
Swing up/down
Automatically
Automatically
MANUAL
MANUAL
Five stages of adjustment
Five stages of adjustment
can be made between
can be made between
0° ~ 61°.
14° ~ 36°.
Heat Pump Model
COOL / DRY Operation
HEAT Operation
AUTO
AUTO
– When the discharge air
temperature is low such
as at the start of heating
operation, the air blows
36°
at horizontal level. As
the temperature rises,
the hot air blows at a
Swing up/down
downward direction.
Automatically
– To stop this op-eration,
press MANUAL.
MANUAL
MANUAL
Five stages of adjustment
Five stages of adjustment
can be made between
can be made between
14° ~ 36°.
0° ~ 61°.
I Setting the Horizontal Airflow Direction
• Adjust it manually
G Use this air conditioner under the following
conditions:
Cooling Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature
32
23
Minimum Temperature
16
11
Heat Pump Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature-Cooling
32
23
(Maximum Temperature-Heating)
(30)
(-)
Minimum Temperature-Cooling
16
11
(Minimum Temperature-Heating)
(16)
(-)
G Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
G Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
Unit in °C
During Soft Dry operation, the indoor fan operates at
Low fan speed.
Outdoor
DBT
WBT
HEAT – Heating Operation
(for Heat Pump Model only)
26
43
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
11
16
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
Unit in °C
unit.
Outdoor
FAN – Air Circulation Operation
DBT
WBT
(for Cooling Model only)
43
26
When the room temperature reaches the set
(24)
(18)
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
16
11
2°C below the set temperature.
(-5)
(-6)
(It is useful when using a heater).
6