The functioning principle of the peristaltic pump is based on the pressure and release of the hose by the
roller holder. This is moved by the motor. The double action of pressure and release of the hose generates
a suction force along the hose that sucks the chemical and pushes it to the output. The flow depends on the
speedy of rotation of the motor and on the diameter of the hose.
1T/2TT pump is equipped with 1/2 power supply cables for temporized dosing, the pump is
Multivoltage 24-230 VAC 50/60Hz (see fig.1)
Load Timer (ONLY FOR 2TT): Trimmer (B) – Power supply cable (E)
Dosing time can be set from 1 to 240 seconds with the trimmer (B)
Top-up Timer: Trimmer (H) – Power supply cable (F)
Dosing time can be set from 1 to 30 seconds with the trimmer (H)
Unscrewing the central knob in the front panel of the pump it is possible to open the transparent cover and
access to the hoses of the pump head. The pump does not dose without the transparent cover even if the
roller holder is rotating.
The pump is built into a polypropylene box, easy to install
The pump is equipped with 1 Led (A), just up the time-control trimmer (B) (H) (see fig.1)
The led shows the following states of functioning : RED LIGHT: power from load cable, GREEN LIGHT:
power from Top-up cable
Flashing Led: the pump is powered and it is dosing according to timer setting
Fixed Led: the pump is powered and it has complete its dosing time
Fast Flashing Led (Both): the pump is stopped, Alarm condition (check the power supply)
Our pumps are built according to the actual general directives endowed with CE mark in conformity with the
following European directives:
n° 2004/108/CE " e s.m.i.
n° 2006/95/CE "DBT Low Voltage Directive" e s.m.i.
n° 2011/65/UE , 2012/19/UE "direttive RoHs e WEEE" e s.m.i.
Connect the 4x6 hose (internal diameter 4 mm, external 6 mm) to the suction nipple (1) and foot filter.
Connect the 4x6 hose(internal diameter 4 mm, external 6 mm) to the delivery nipple (2) and injection valve.
Tighten nuts (3 and 4)
Try to keep both the suction and discharge hose as straight as possible, avoiding all unnecessary bends.
Install the pump away from sources of heat and in a dry place at a maximum environment temperature of
40°C.
The minimum operating temperature depends on the liquid dosed that has to remain in a liquid state.
For fixing the pump to the wall use the screws and the label supplied with the pump. Stick the label to the wall
and make the holes in the 2 points of the label that correspond to the F points of the bracket like in FIG.3.
Block the bracket to the wall and then the pump to it. Bracket for wall mounting (FIG.4)
ADSP7000471 – 17/04/2014

FUNCTIONING PRINCIPLE

TECHNICAL CARACTERISTICS (FIG.1)

DESIGN STANDARD

INSTALLATION (FIG.2 and FIG.3)
ATTENTION
WALL MOUNTING (FIG.4)