Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
2)
Position the powermister and fill the tank with liquid.
3)
Ensure the brakes are applied before using the machine.
4)
Point the machine on the right direction. Direct it a little upwards so that the fog will also reach the ceiling.
5)
Make sure the hose is not kinked and that the water pump is always fully sumberged (depending upon the type
of pump).
6)
To clean the motor and the filter run the Powermister just with clean water after having used disinfectant or
medicine in the machine.
2.3

Using the Powermister:

Start
1)
Direct the machine towards the area you want to spray
2)
Turn on the fan.
3)
Open the water supply.
4)
Turn on the disc and the pump.
Stop
1)
Shut off the water supply.
2)
Turn off the disc and the pump.
3)
Turn off the fan.
4)
Remove the electric plug from the mains supply.
3.

Safety measures

Always take good notice of safety precautions, which are written in order to prevent accidents and to ensure
that machines are used correctly
Carefully read the safety instructions before use, and keep them in a readily accessible place.
When lifting the Powermister, don't lift it by the top (fan)assembly.
Don't turn the fan by hand.
Switch off the mains power before attempting any repair.
Please ensure that you do not spray onto any electrical equipment when using the Powermister.
Fire or electric shock could result.
Do not introduce your hand or any other objects into the rotating part or inside any safety grating. Never
remove any safety grating.
Regularly check that all components are properly tight. If the rotating disc becomes loose, it can be dangerous.

Product specifications:

Measurements ( b x l x h ):
Weight:
Motor40 :
Fan:
Dimensions of Fan:
Dimension of spray nozzle:
4.

Pump options

There is no pump included as standard. Users can choose between a standard pump (8806706), a stainless steel pump
(0809905) or a peristaltic pump (0803701). The choice will depend upon the type of chemicals that will be used.
8806706 (220 V)
12
550 x 650 mm x 1500 mm
33 kg
0,4 KW/ Rotating disc: 3600 RPM,
1700 RPM
300~500Ø
20~40 µm
0803701