Descargar Imprimir esta página

Hansgrohe Exafill 58127 Serie Instrucciones De Montaje página 21

Publicidad

Assembly
turn off water
Install tub with Exafill and connect to pipe
system
Testfilling of the bath tub.
Flushing of the pipes. (mixer open - test
inlet open) (Fig. 2)
Pressure test of the pipes between mixer
and flush plug (flush plug closed - mixer
open) (fig. 3). Test pressure max. 1
MPaPressure test max. 10 min
Check installation for tightness (Fig. 4)
close mixer afterwards!
Ibox in combinaton with an Exafill bath filler
with overflow and waste
Turn off the water at the shut off valve for
the supply pipe to the exafill
Disassemble the flush body
Insert plug in outlet for Exafill
Install flush body
Water can be opened again, feeder line to
Exafill is blocked by the plug
The residual water jet during pressure test is
taken into account. It shall remind you of closing
the mixer after the pressure test and avoid cross
flow at the mixer.
Colour set installation see page 6
5

Publicidad

loading