Unpacking
1.
Remove unit from carton and
discard all packaging.
HOW TO SET UP YOUR
UNIT
Location of the Air Compressor
Locate the air compressor in a clean,
dry and well ventilated area. The air
compressor should be located at
least 12" away from the wall or other
obstructions that will interfere with
the flow of air. The air compressor
pump and shroud are designed to
allow for proper cooling. The ventila-
tion openings on the compressor are
necessary to maintain proper operat-
ing temperature. Do not place rags or
other containers on or near these
openings.
GROUNDING INSTRUCTIONS
Risk of Electrical
Shock. In the event
of a short circuit, grounding
reduces the risk of shock by pro-
viding an escape wire for the elec-
tric current. This air compressor
must be properly grounded.
The portable air compressor is
equipped with a cord having a
grounding wire with an appropriate
grounding plug (see following illustra-
tions). The plug must be used with
an outlet that has been installed and
grounded in accordance with all local
codes and ordinances.
1.
The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a
grounded outlet.
D28071

ASSEMBLY

INSTALLATION

IMPORTANT: The outlet being used
must be installed and grounded in
accordance with all local codes and
ordinances.
2.
Grounding Pin
3.
4.
grounding can result in electrical
shock.
Do not modify the plug provided. If
it does not fit the available outlet, a
correct outlet should be installed
by a qualified electrician.
Repairs to the cord set or plug
MUST be made by a qualified elec-
trician.
10- ENG
Make sure the outlet being used
has the same configuration as
the grounded plug. DO NOT
USE AN ADAPTER. See illustra-
tion.
Plug
Inspect the plug and cord before
each use. Do not use if there are
signs of damage.
If these grounding instructions
are not completely understood,
or if in doubt as to whether the
compressor is properly ground-
ed, have the installation checked
by a qualified electrician.
Risk of Electrical
Shock. Improper
Grounded
Outlets