Max. working area
Air flow step 1
Air flow step 2
Dehumidifying at 27˚C and 60% r.h.
Dehumidifying at 30˚C and 80% r.h.
Power at 27˚C and 60% r.h.
Tank volume
Cooling medium, freon-free
Dimensions in mm., L x B x H
Weight
Noise level in decibels
PROBLEM
Dehumidifier does not start
Does not dehumidify
High noise level
Ice formation on cooling coils
No water enters reservoir
Does not turn off when water
reservoir is full
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier
03
TECHNICAL DATA
DS12F
DS15F
90 m
3
100 m
3
256 m
3
/hour
256 m
3
/hour
-
520 m
/hour
3
6.1 l/day
6.7 l/day
11.1 l/day
12.0 l/day
220W/hour
240 W/hour
10.4 litres
10.4 litres
R134A
R134A
343 x 406 x 527
343 x 406 x 527
22 kg.
22 kg.
38 dB
38-58 dB
SOLUTION
-
Check that dehumidifier is connected to electricity and that fuse has not gone
-
If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier.
Check that float is free
-
Check that hygrostat is working. Dehumidifier should start when hygrostat is in Maximum position
-
Check that fan is spinning
-
Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean and dehumidifier should stand
20-30cm from wall
-
Listen for sound of compression, but bear in mind that the dehumidifier may be in a dehumidifying cycle, when the compression stops. Wait initially for about 35
minutes.
-
Check that a thick coating of ice has not formed on the cooling coils.
-
Increase distance between dehumidifier and surrounding surfaces
-
Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils
-
Remove air filter at rear of dehumidifier and check that no dust or fluff is obstructing passage of air through machine
-
Timer which controls defrosting may be broken, in which case compression will not stop regularly
-
Check for obstruction to drip-tray above water reservoir
-
It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping
DS28F
DS36F
140 m
3
190 m
3
190 m
3
/hour
197 m
3
/hour
336 m
/hour
336 m
/hour
3
3
10.4 l/day
13.2 l/day
17.5 l/day
20.8 l/day
460 W/hour
510 W/hour
10.4 litres
10.4 litres
R134A
R134A
343 x 406 x 527
343 x 406 x 527
24 kg.
26 kg.
38-58 dB
38-58 dB
ED50F
ED50Feco
230 m
3
330 m
3
129 m³/hour
172 m
3
/hour
296 m
/hour
400 m
/hour
3
3
21,1 l/day
25,2 l/day
33,2 l/day
40 l/day
850 W/hour
790 W/hour
10.4 litres
10.4 litres
R410A
R410A
343 x 406 x 527
343 x 406 x 527
28 kg.
28 kg.
38-58 dB
38-58 dB