http://waterheatertimer.org/GE-timers-and-manuals.html#15306
15350
SWITCH:
CONTACT RATINGS:
TIMING MOTOR:
POWER CONSUMPTION: 3 WATTS MAX
For seperate motor terminals, remove
bridge from terminals L & 1
120VAC/60Hz
We recommend that installation be made by a licensed electrician.
Disconnect power at main panel prior to installing or servicing this
time switch or the equipment connected to it.
Connect in accordance with national and local electrical codes.
Supply Connections: Use gauge specified (AWG #8-14 ) suitable for 75
(167
F).
º
Replace insulator before turning on electricity to unit.
INSTALLATION AND OPERATING INSTRUCTIONS TO SET ON AND
OFF TIMES:
Dark trippers turn OFF. Place tripper
on dial edge as shown in figure and set
point of each tripper to desired operat-
ing time. Note if selected time is AM or
PM. Hold tripper against dial edge and
firmly tighten knurled screw.
INSTALLATION AND OPERATING INSTRUCTIONS
TO SET DIAL TO TIME:
Turn dial counter-clockwise until correct time is indicated by
arrow on nameplate.
FOR TEMPORARY MANUAL OVERRIDE:
Press down lever on right of nameplate to turn ON. Press down
lever on left of nameplate to turn OFF. CAUTION: Do not rotate
dial for manual override.
TO REMOVE MECHANISM FROM CASE:
Press lever near case latch to release mainplate and swing the
movement out. To replace, insert mainplate projections in slots
opposite latch and swing movement in until it latches.
15350
MANUAL VERSION 1
12/15/09
WWW.JASCOPRODUCTS.COM
HEAVY DUTY
MECHANICAL
TIME SWITCH
24 HOUR TIME SWITCH
SPST
40 AMP 120-277VAC
40 AMP TUNGSTEN 120VAC
20 AMP INDUCTIVE
120VAC 60Hz
Light trippers turn ON.
1000VA (120-277) PILOT DUTY
120-277VAC SINGLE PHASE
2HP 120VAC; 5HP 240VAC
L
H
Removable
N
Bridge
OFF TIME
(Dark Tripper)
MANUAL
O
F
OFF
F
LEVER
LR21743
1101
M
2
1
X
LOAD
FOR 120 VAC
Dial Calibrations
Knurled Screw
ON TIME
(Light Tripper)
MANUAL
O
N
GE5360-41K2
C
º
ON
LEVER
469D