955191.book : I95519US.FM Seite 3 Montag, November 23, 1998 11:03 AM
English
3
Maintenance and Care
Maintenance
For Maintenance, see fold-out page II.
Shut off cold and hot water supply.
I. Ceramic cartridge
Unscrew the ceramic cartridge (3, 4) using a
17mm (11/16") wrench.
II. Check valve, see fold-out page II.
Screw off connection nipple (G) and replace check
valve (11).
III. Diverter, see fold-out page II.
1.Remove clip (H) and pull off spout (8).
2.Pull out the diverter (9) and clean.
IV. Flow regulator, see fold-out page II.
Unscrew and clean flow regulator (8.1).
Check, clean and if necessary replace parts.
Grease with special valve grease (Cat.No. 18 012).
Assemble in reverse order.
Only original Grohe replacement parts may
be used.
Care
Instructions for care of this wideset will be found in
the Limited Warranty supplement.