Important information about the ThinkStation
Static Rail Kit
This document provides important information about the ThinkStation
If you want to install a ThinkStation computer into a rack, you need one set of rails. The
set of rails is designed for fixing a 4U ThinkStation computer into a rack without the
flexibility of sliding in or out. ("U" is the unit of measurement for defining the vertical space
used by your ThinkStation computer and 1U is equivalent to 4.445 cm or 1.75 inches.)
Your rail kit package contains:
One set of rails
Two locking clips
Documentation
If any item is missing or damaged, contact your place of purchase. Ensure that you retain
your proof of purchase and packing material. They might be required to receive warranty
service.
About the rack
CAUTION: Be sure to read and understand the documentation that comes with the
rack for safety and cabling information. Before you install a workstation into the
rack, also ensure that you read and understand all safety information and
guidelines in this document. Reading and understanding the information reduces
the risk of personal injury and damage to your product.
The rack must meet one of the following requirements:
Standard 4-post (square-hole), 19-inch rack configuration compliant with EIA-310-E
as defined by the Electronic Industries Alliance
Standard 4-post (unthreaded round-hole), 19-inch rack configuration compliant with
EIA-310-E as defined by the Electronic Industries Alliance
The dimensions of the rack must meet the following requirements:
Rear mounting flange
Front mounting flange
Rack front door
The following table explains the dimension requirements of the rack.
Item
Dimensions
Description
A
609.6 – 914.4 mm
Item A refers to the distance between the front
(24 – 36 inches)
mounting flange
and the rear mounting flange
. The distance must be 609.6 mm (24 inches) in
minimum and 914.4 mm (36 inches) in maximum.
B
> 474 mm
Item B refers to the internal width of the rail kit. The
width must exceed 474 mm (18.66 inches).
(18.66 inches)
D
> 60 mm
Item D refers to the distance between the front
mounting flange
and the inside of the rack front
(2.36 inches)
door
. The distance must exceed 60 mm (2.36
inches). This clearance is required for the chassis
pull handles on the front of the ThinkStation
computer as well as air circulation through the rack.
L
> 950 mm
Item L refers to the distance between the front
mounting flange
and the rear of the rack. The
(37.4 inches)
distance must exceed 950 mm (37.4 inches).
Read these guidelines first
Before you install the ThinkStation computer into a rack, review the following guidelines.
The guidelines help you in your installation and avoid the risk of personal injury and
damage to your product.
Two or more people are required to lift a ThinkStation computer, move a ThinkStation
computer, or install a ThinkStation computer into a rack. You also can use a workstation
computer-lifting tool for help.
≥ 18 kg (39.7 lb)
≥ 32 kg (70.5 lb)
< 32 kg (70.5 lb)
< 55 kg (121.2 lb)
CAUTION
Use safe practices when lifting.
Before installing a ThinkStation computer into a rack, remove all media from the
drives and turn off all attached devices and the ThinkStation computer. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are
connected to the ThinkStation computer.
ThinkStation Static Rail Kit
http://www.lenovo.com/support
Ensure that the room air temperature is below 35°C (95°F).
Do not block any air vents; usually 15 cm (6 inches) of space provides proper airflow.
Do not leave open spaces above or below an installed ThinkStation computer in your
rack. To help prevent damage to ThinkStation computer components, always install a
blank filler panel to cover the open space and to help ensure proper air circulation.
Install the ThinkStation computer only in a rack with perforated doors for both security
and proper airflow.
Start from the bottom of the rack for the ThinkStation computer or device installation.
Install the heaviest ThinkStation computer or device in the bottom of the rack.
®
Static Rail Kit.
Do not extend more than one ThinkStation computer or device out of the rack at the
same time.
If possible, remove the doors and side panels of the rack to provide easier access
during installation.
Do not overload the electrical outlet when you install multiple devices in the rack.
Connect all power cords to proper electrical outlets and properly manage all the
cables in the rack. Refer to the documentation that comes with the rack about
managing cables.
Do not place any object on top of rack-mounted devices.
When you move or ship the rack, properly handle the installed ThinkStation
computers first. Refer to the documentation that comes with the rack and the
documentation that comes with each rail kit for detailed information.
Installing a ThinkStation computer into a rack
(with static rail kit)
Before you begin, remove all the parts from the rail kit package and lay all the parts on a
working surface. Measure the rack before the installation to ensure that the rack can
accommodate the static rail.
Note: The holes in a mounting flange are separated into groups by measuring marks. The
three holes between two adjacent measuring marks form a group, which indicates 1U
space. Note the measuring marks on a mounting flange to help you correctly select a rack
mounting area for the ThinkStation computer. For more information about the placement
of the holes in a mounting flange, refer to the documentation that comes with the rack.
To install a ThinkStation computer into a rack, do the following:
Install the rail kit by doing the following:
1.
a. Select a proper rack mounting area for the left static rail. Position the rear end of
the left rail to the mounting area. Ensure that the tabs on the rear end of the rail
are aligned with the corresponding holes in the mounting area. Press the latch
and push the rail until the rear end of the left static rail is firmly secured to the
mounting flange.
If the holes in a mounting flange are round, the installation method is the same.
Press the latch
inserted into the corresponding holes. Then, the rear end of the rail is firmly
secured to the mounting flange.
b. Position the front end of the left static rail to the mounting flange. Ensure that the
front end and rear end of the left static rail are at the same horizontal level. Press
the latch
mounting flange.
If the holes in a mounting flange are round, the installation method is the same.
Press the latch
inserted into the corresponding holes. Then, the front end of the rail is firmly
secured to the mounting flange.
≥ 55 kg (121.2 lb)
< 100 kg (220.5 lb)
c. Repeat steps a through b to install the right static rail to the opposite side of the
rack.
Second Edition (March 2017)
© Copyright Lenovo 2015, 2017.
Lenovo, the Lenovo logo, ThinkPad, and the ThinkPad logo are trademarks of Lenovo in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services Administration "GSA" contract, use, reproduction, or disclosure is subject to restrictions set forth in
Contract No. GS-35F-05925.
and push the rail until the inner round posts of the tabs are
and push the rail until the front end of the rail is firmly secured to the
and push the rail until the inner round posts of the tabs are
PN: SP40K32881
Printed in China
Remove the two screws on the side of the locking clip and install the locking clip on
2.
the mounting area above the left rail. Then install the two screws to secure the
locking clip on the mounting area.
Repeat step 2 to install the other locking clip to the opposite side of the rack.
3.
Remove the four feet on the bottom of the ThinkStation computer.
4.
Position the ThinkStation computer onto the rails. Then slide the computer to the
5.
rear of the rack until the computer handles are aligned with the installed locking clips.
Note: When you move or ship the rack, remove the ThinkStation computer secured
by the rail kit from the rack first.
Press the buttons on the locking clips to secure the ThinkStation computer.
6.

Publicidad

loading

Resumen de contenidos para Lenovo ThinkStation

  • Página 1 © Copyright Lenovo 2015, 2017. Lenovo, the Lenovo logo, ThinkPad, and the ThinkPad logo are trademarks of Lenovo in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others.
  • Página 2  Je-li to možné, sejměte z racku dveře a boční panely. Usnadníte si tak přístup při Sada kolejnic je určena k umístění počítače ThinkStation o rozměru 4 U do skříně typu instalaci. rack, přičemž nainstalovaný počítač nelze vysouvat a zasouvat. („U“ je měrná jednotka určující...
  • Página 3 Befestigungsflansch verbunden. als 950 mm sein. Lesen Sie zuerst diese Anleitung Beachten Sie die folgende Anleitung, bevor Sie den ThinkStation Computer in einem Rack installieren. Die Richtlinien enthalten Hinweise zum Einbau sowie zur Vermeidung von Verletzungen und Beschädigungen des Produkts.
  • Página 4 Si desea instalar un equipo ThinkStation en un bastidor, necesitará un conjunto de rieles. bastidor. El conjunto de rieles está diseñado para fijar un equipo ThinkStation 4U a un bastidor sin  No extienda más de un equipo ThinkStation o dispositivo fuera del bastidor al mismo la flexibilidad de desplazamiento hacia dentro o afuera.
  • Página 5  Commencez par installer les périphériques ou l'ordinateur ThinkStation par le bas de Pour installer un ordinateur ThinkStation dans une armoire, vous avez besoin d'un jeu de l'armoire. glissières. Ce jeu de glissières est conçu pour fixer un ordinateur ThinkStation 4U dans ...
  • Página 6: Leggere Prima Quanto Segue

     Installare il computer ThinkStation o il dispositivo più pesante nella parte inferiore del rack. binari. La serie di binari è stata progettata per il fissaggio di un computer ThinkStation 4U  Non estendere più computer ThinkStation o dispositivi contemporaneamente fuori dal in un rack senza la flessibilità...
  • Página 7  室温が 35°C (95°F) 以下であることを確認します。 位置にロック・クリップを固定します。  通気口をふさがないでください。通常、15 cm (6 インチ) のスペースがあれば空気が 正しく流れます。  ラックに ThinkStation コンピューターを搭載する場合は、上下にスペースを残さな いでください。スペースが残る場合は、ThinkStation コンピューターのコンポーネン ThinkStation Static Rail Kit に関する重要な情報 トの破損を防止するため換気用のブランク・フィラー・パネルを取り付けてそのスペ ースを埋めてください。 ® 本資料には、ThinkStation Static Rail Kit に関する重要な情報を記載しています。  ThinkStation コンピューターは、セキュリティーおよび適切な換気の両方を確保する ThinkStation コンピューターをラックに取り付ける場合は、レール 1 セットが必要です。 ため、穴の開いたカバー付きラックにのみ取り付けます。...
  • Página 8  Begin aan de onderkant van het rek met de installatie van de ThinkStation-computer Als u een ThinkStation-computer in een rek wilt installeren, hebt u één set rails nodig. De of het apparaat. set rails is bestemd voor de bevestiging van een 4U ThinkStation-computer in een rek ...
  • Página 9 O conjunto de trilhos foi desenvolvido para fixar computadores rack. ThinkStation 4U em um rack sem a flexibilidade de deslizar para dentro ou para fora. ("U"  Não estenda mais de um computador ThinkStation ou dispositivo para fora do rack ao é...
  • Página 10 смещения. (U — это единица измерения для определения вертикального пространства, используемого компьютером ThinkStation. Значение 1U эквивалентно  Не выдвигайте из стойки более одного компьютера ThinkStation или устройства 4,445 см.) одновременно. Если это возможно, снимите дверцы и боковые панели стойки для облегчения...
  • Página 11 Na zdvihnutie počítača ThinkStation, jeho presun alebo inštaláciu do stojana sú potrebné najmenej dve osoby. Môžete si pomôcť aj nástrojom na zdvíhanie pracovnej stanice. ≥ 18 kg (39,7 lb) ≥...
  • Página 12 ürünün zarar görme riskini engeller. Bir ThinkStation bilgisayarını kaldırmak, ThinkStation bilgisayarını taşımak veya ThinkStation bilgisayarını bir rafa kurmak için iki veya daha fazla kişi gereklidir. Ayrıca bir iş istasyonu bilgisayarını kaldırma aracından da yardım alabilirsiniz. ≥ 18 kg (39,7 lb) ≥...
  • Página 13 ThinkStation Static Rail Kit http://www.lenovo.com/support  请勿挡住任何通风孔;通常情况下,留出 15 厘米(6 英寸)的空间可确保空气正常流 通。  请勿在安装于机架中的 ThinkStation 计算机上下留出开放空间。为帮助防止 ThinkStation 计算机组件损坏,请始终安装空白填充面板以填充开放空间并帮助确保空 气正常流通。 有关 ThinkStation Static Rail Kit 的重要信息  只能将 ThinkStation 计算机安装在挡板穿孔的机架中以确保安全和空气正常流通。  从机架底部开始安装 ThinkStation 计算机或设备。 ® 本文档提供有关 ThinkStation Static Rail Kit 的重要信息。 ...
  • Página 14 本文件提供 ThinkStation ® Static Rail Kit 的相關重要資訊。  從機架底部開始安裝 ThinkStation 電腦或裝置。 如果您想要將 ThinkStation 電腦裝入機架,您需要一組導軌。這組導軌的設計是為了將 4U  將最重的 ThinkStation 電腦或裝置安裝在機架底部。 ThinkStation 電腦固定在機架中,但是不提供滑入或滑出的彈性。(「U」是一種測量單 位,用於定義 ThinkStation 電腦所佔的垂直空間;1U 相當於 4.445 公分或 1.75 吋)。  請勿同時將多部 ThinkStation 電腦或裝置伸出機架。 您的導軌套件包裝內含:  如果可能,請卸下機架的門板和側面面板,以便在安裝時更容易接觸。  一組導軌  在機架中安裝多個裝置時,請勿使電源插座超載。...