Main Components - CAME STRAUSS LIGHT KLT Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
Dimensions

Main components

1. UP button
2. Programming button
3. SUN button
4. Indicator LED
5. Double-sided adhesive film
6. Sun sensor
Description of button functions
Programming: for memorising the device.
UP button: this is used to control the moving part up to the upper limit switch.
SUN button: if pressed once, this is used to check the selected level of sensor sensitivity, and at the same time check which
operating mode the sensor is programmed in. If pressed several times in succession, it can also be used to vary
the sun sensor intervention threshold level. Each press changes the level sequentially 0-1-2-3-4-0.....
ADJUSTMENTS
SUN button: adjusting the sun threshold sensitivity level: 15 klux (+ sensitive) / 60 klux (- sensitive).
Checking ambient brightness
Press P2 and SUN at the same time for three seconds.
Release the buttons when LED 0 comes on. The sensor performs the test and reports the current brightness level. If LED 0 stays
on, the brightness is below level 1.
Press any key to exit the test, otherwise after 2 minutes, the sensor will automatically exit the test.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

119t70575

Tabla de contenido