Descargar Imprimir esta página

GRAFF GX-8950 Instrucciones De Instalación página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

SHOWER BODY ASSEMBLY
1)
The hot and cold water supply system should be installed and the
mixer tap connected observing the following recommendations:
• the hot water coupling should be located on the right and the cold
water coupling should be located on the left,
• coupling spacing: 5-7/8" ± 13/16" (150 mm ± 20 mm),
• recommended installation height for the mixer tap: 35-7/16" -
39-3/8" (900-1000 mm) from the finished floor.
Fit the dog-leg connectors (41), (40), (9) to the pipe sections
2)
where they exit the wall, first sealing them with teflon tape or other
sealant, making sure that the dog-leg connector outlets are set at
equal height with the end faces at equal distances from the wall and
that the distance between openings matches the distance between
those of the connecting nuts (4) of the shower body (1).
Screw decorative sleeves (6) onto eccentric connectors (9) until you
3)
feel strong resistance.
4)
Slide rosettes (8) with O-rings over connection nuts (4) and move
them further onto the tap body connector pipes (fig. 2.2).
5)
Insert gaskets (5) into connection nuts (4) and screw them onto
eccentric connectors (9) using an open end adjustable wrench. In
order not to scratch the decorative surface of nuts (4) , put plastic
washers under the wrench (fig. 2.3).
Slide the rosettes (8) down carefully and push them to the finishing
6)
wall.
7)
Carry out performance test of connected tap. If you notice any leaks,
remedy by tightening the connections.
r
a t e
l d w
f r í a
C o
u a
A g
r
a t e
t e
t w
i e n
H o
c a l
u a
A g
9
41
40
"
/ 1 6
± 1 3
/ 8 "
5 - 7
Carefully install the connection body brazing (10), (11) on the stub of the mixer-tap body (1).
1)
2)
Slide the shower post (shower head arm) (13) on the connection body brazing (11) with care not to damage the o-rings. Align the shower
post (13) and fasten with the screws (35) (fig. 3.1). Finally, install the mounting plug (20) on the arm stub (39) (fig. 3.1., 3.2.).
Align the mounting plug (20) with the finished wall surface to keep the two mounting plug holes level. Mark the drilling points through the
3)
holes (fig. 3.2).
4)
Carefully undo the shower assembly (10), (11) and (13) from the mixer-tap body. Put it carefully aside in a safe place.
5)
Drill Ø5/16" holes at the marked points on the finished wall. Make sure that the hole spacing is as shown in fig. 3.2. Place the rawlplugs (23)
in the drilled holes. Fasten the mounting plug (20) to the wall with the screws (22) and leave a large play on the screws to easily install the
shower assembly (10), (11) and (13) (fig. 3.3).
Slide the assembled shower (10), (11) and (13) on the mixer-tap body (1) stub with care not to damage the o-rings (37). Align the shower
6)
assembly. Having aligned the connection body brazing (10), fasten the whole assembly with the screw (38). Remember to install the decorati-
ve cover (19) on the mounting plug (20) (fig. 3.4). Tighten the screws (22) home.
Slide the decorative cover (19) with the o-ring seal (18) carefully to the installed mounting plug (20). Bring it home with the finished wall.
7)
Secure the assembly with the top screw (21). It is very important to keep the entire assembly vertical.
Tighten the rainshower (12) nut to the shower post (13) arm. Mind proper location of the rubber gaskets (16) and the orifice (17) within
8)
the rainshower nut (fig. 3.5).
IOG 5019.00
6
6
2.1
LOWER AND UPPER ARM ASSEMBLY AND THE SHOWER HEAD
THERMOSTATIC SHOWER COLUMN
COLUMNA DE DUCHA TERMOSTÁTICA
INSTALACIÓN DEL CUERPO DE DUCHA
1)
Conecte la instalación del agua caliente y fría al lugar de instalar la
batería siguiendo las recomendaciones:
• la acometida del agua caliente por el lado izquierdo, la acometida
de la fría, por el derecho,
• la distancia ente las acometidas debe caber dentro de los límites:
5-7/8" ± 13/16 " (150 mm ± 20 mm)
• la altura recomendada de la instalación de la batería: 35-7/16" -
39-3/8" (900-1000 mm) sobre el nivel del suelo.
En las secciones de la instalación acabadas con rosca interna G1/2"
2)
enrosque las piezas de unión excéntricas
uniones con la cinta de teflón (u otro tipo de guarniciones) – haga caso
que los ejes excéntricos (9) por el lado de la rosca G3/4" se encuentren
en la misma altura, las superficies frontales tengan la misma distancia
de la pared, y el espacio entre los huecos sea igual que la
distancia entre los ejes de las tuercas (4) del cuerpo ducha (1).
3)
En los conectores excéntricos (9) enrosque los casquillos decorati-
vos (6) hasta sentir una resistencia.
4)
Introduzca las rosetas (8) con juntas tóricas en las tuercas de unión
(4) desplazándolas hacia los tubos de conexión de la grifería (fig.
2.2).
5)
En las tuercas de unión (4) meta las juntas (5) enroscándolas en los
conectores excéntricos (9) con la llave ajustable plana. Para evitar
rayado de la superficie decorativa de las tuercas (4) coloque arande-
las de plástico debajo de la llave plana (fig. 2.3).
Con cuidado cierre las rosetas (8) acercándolas a la superficie de la
6)
pared de acabado.
7)
Realice una prueba de funcionamiento de la grifería conectada a la
alimentación. Si se observan fugas, elimínalas apretando las
uniones.
8
4
9
1
2.2
4
(41), (40), (9)
, aislando las
6
9
5
1
Rev. 2 August 2019
8
2.3
2.1

Publicidad

loading