8 English
Switching on and off must be carried out by
means of the switch on the hot-air blower and
never by inserting or extracting the plug from
EN
the mains socket!
The hot-air blower must be kept out of reach
of children!
Do not use as hair-drier (Danger of burns!)!

Initial operation

Before the first operation check that the mains
voltage corresponds to that given on the machine
nameplate.
The electronic hot-air blower 1600 HLG E is so
constructed, that it may be used without difficulty
and without accessories
1. as a manual hot-air blower
2. as a table hot-air blower in horizontal operation
(using a pull-out support)
3. as a table hot-air blower in vertical operation (as
standing hot-air blower like e.g. a Bunsen burner).
Switch with locking button for continu-
ous operation
By pressing the switch (1) on the handle the hot-
air blower is put into operation. For continuous op-
eration the locking button (2) at the side is pressed
down as well. To switch off again after continuous
operation simply press locking button once again
and it springs automatically up again.
Setting the temperature
The temperature is set by means of a rotary po-
tentiometer (6), the range of which is marked by
the numbers 1–6. The numbers are identical with
the approximate working temperature, e.g. 2 =
200 °C, 6 = 600 °C.
The hot-air blower produces constant hot air only
after a few minutes operation, as all elements
must first be heated up or in the case of tempera-
ture reduction, first cooled down.
Horizontal operation
The support (7) for horizontal operation can be
locked in place by pulling it out until it catches. By
pressing down the pull-out support slide in the
housing, the support can be pushed back into the
housing again.
1600_HLG_E-EN / 1005
Mains cable
Damaged mains cables must not be used. They
are to be replaced immediately by an electrician.

Noise/vibration information

Measured values correspond with EN 60745.
Sound pressure level: = 65.8
Sound power level: = 76.8
Work place emission value:= 66.1
The weighted acceleration is typically smaller than
2
2.5 m/s
.
In the interests of technical progress, all data are
subject to alteration without notice.
Some sample applications
Paints and enamels can be cleanly removed
with the aid of a spatula (potentiometer posi-
tion 3–6 as required).
Frozen water pipes can be thawed without
damage (temperature may be adjusted as re-
quired).
Take care when working near wooden
walls and wooden false ceilings. In-
creased danger of fire or smouldering fire!
Removing wallpaper with the aid of hot air,
especially useful in the case of ingrain wallpa-
pers.
Loosening fitted carpets from below.
Remove the subsoil from the car.
Removing inconvenient stickers from cars.
Remove blisters from PVC stickers by warm-
ing.
Waxing skis.
Repairing of skis and surfboards and other
sporting equipment.
Staining wood with hot air instead of using
dangerous flames.
Sterilizing.
Expansion of hoses and plastic pipes.
Repair of enamel defects.
Soldering with tin solder, as well as tin coating
of car body- and sheet-metal parts (potenti-
ometer position 6 = max. temp.).
Dry paints and knifing fillers with hot air (po-
tentiometer position 1–4, depending on per-
missible temperature).
Contraction of packings (potentiometer posi-
+3
dB (A)
+3
dB (A)
+3
dB (A)