ALSIR-2000 SIREN
EN
1. Place batteries
Open the Siren by unscrewing the two screws beneath the light cap. When the screws are removed
the cap of the Siren can be slid open. When the cap of the Siren is slid open place 4x Alkaline D type
1.5V battery in the Siren.
Observe the correct polarity of the batteries. When the battery is low the
Siren will give 1 beep every 5 seconds while entering arm/disarm mode for the duration of 3 minutes.
2. LED indicator
The Siren has a LED indicator in the light cap. The LED behaviour is as followed.
Confirm pair: LED will blink 5 times
Confirm unpair: LED will blink 5 times
Learn mode: LED will blink for 15 sec.
3. Learn mode
When the Siren is disarmed slide open the cap and press and hold the Siren learn button for about 2
seconds to enter learn mode. The LED of the Siren will be blinking (in the light cap). The learn mode
lasts 15 seconds. While in learn mode press the SET button on a sensor to pair it with the Siren (check
manual of the sensor how to pair it). The LED of the Siren will flash quickly 5 times to confirm the
pairing was successfully. Close the cap of the Siren.
4. Arm the ALSIR
To arm the Siren press and hold the ON button for 4 sec on the ALKCT-2000.
If the Siren is armed successfully the LED on the ALKCT will light up for 1.5 seconds.
5. Walk-out time
When the Siren is armed there is a 85 sec walk-out time. Within these 85 sec the system checks all
the sensors if they are responding and it is possible to leave the building without triggering the alarm.
When at the beginning of the walk-out time a window or door is open the alarm will go off for 20 sec
reminding that one of the doors or windows isn't closed. After the window or door sensor is closed
the alarm will stop and continue in armed mode.