Installing a domestic appliance can be a complicated operation which if not carried out correctly, can seriously affect consumer
safety. It is for this reason that the task should be undertaken by a professionally qualified person who will carry it out in
accordance with the technical regulations in force. In the event that this advice is ignored and the installation is carried out
by an unqualified person, the manufacturer declines all responsibility for any technical failure of the product whether or not
it results in damage to goods or injury to individuals.
BUILT-IN
The furniture in which your hob will be installed and all adjacent
furniture, should be made from materials that can withstand high
temperatures. In addition, all decorative laminates should be fixed
with heat-resistant glue.
Installation:
• A watertight seal is supplied with the hob.
Before fitting:
- turn the hob upside down, with the glass surface facing downwards.
Make sure the glass is protected.
- fit the seal round the hob.
- make sure that it is correctly fitted to avoid any leakage into the
supporting cabinet.
• It it important to fit the hob on a level supporting surface.
• Deformations caused by incorrect fitting can alter the specifications
of the worktop and the performance of the hob.
• Leave a gap of at least 5 cm between the appliance and any
neighbouring vertical surfaces.
• It is absolutely essential that the recess conforms with the
dimensions indicated.
• The height of the flush-mounted part of the hob is 5,5 cm.
• If there is an intermediate division :
- the clearance between the bottom of the casing and an
intermediate floor or part of a furniture unit must greater than
2,5 cm so as to allow air circulate.
The minimum distance should be 8 cm.
- furthermore, you should ensure that there is at the rear a
ventilation (8 cm) on all the width.
• You can not build the hob in above an oven with no fan, a
dishwasher, fridge, freezer or washing machine.
• The body of the hob is fitted which 4 location holes to take the
fixing clamps intended to fix the hob in the unit. Place the 4 fixing
clamps, before building-in the hob, in such a way that the hob
is placed perfectly in the support unit.
50 mm
Seal
25 mm
mini
Opening
500 X 50

ELECTRICAL CONNECTION

"The installation must conform to the standard directives."
The manufacturer declines all responsibility for any damage that
may be caused by unsuitable or unreasonable use.
Warning :
• Always check before any electrical operation, the supply tension
shown on the electricity meter, the adjustment of the circuit-
breaker, the continuity of the connection to earth to the installation
and that the fuse is suitable.
• The electrical connection to the installation should be made via
a socket with a plug with earth, or via an omnipole cut-out switch
with an opening gap of at least 3 mm.
If the appliance has a socket outlet, it must be installed so that
the socket outlet is accessible.
INSTALLATION
Hob
Opening
500 X 10
2 GB
• The yellow/green wire of the power supply cable must be
connected to the earth of both power supply and appliance
terminals.
• The manufacturer cannot be held responsible for any accidents
resulting from the use of an appliance which is not connected
to earth, or with a faulty earth connection continuity.
• Any queries regarding the power supply cord should be referred
to After Sales Service or a qualified technician.
The hob is fitted with a power supply cord which allows it to
be connected only to a power supply of 220-240 V between
phases or between phase and neutral.
• Connect to a socket, to choose the correct fuse, you must refer
on the table.
It is however possible to connect the hob to :
Two phases 220-240V2~, Threephases 220-240V3~
or Three phases 380-415V3N~.
To proceed to the new connection, you must adhere the following
instructions.
• Before making the connection make sure that the installation is
protected by a suitable fuse, see table, and that it is fitted with
wires of a large enough section to supply the appliance normally.
1- Operations to be carried out on the existing connection :
- turn over the hob, glass side against the work top, taking care
to protect the glass.
- open the cover.
- pull out the supply cord :
. remove the screws retaining the shunt bars and the conductors
of the supply cord,
. unscrew he cable clamp to release the power supplying cord,
. pull out the supply cord.
2- Operations to be carried out to make a new connection :
- choose the power supply cord in accordance with the
recommendations in the table.
- pass the power supply cable into the clamp.
- strip the end of each conductor of the supply cord on a 10 mm
length, by taking in account the requested length of the cord for
the connection to the terminal block.
- according to the installation and with the help of shunt bars which
you should have recovered in the first operation, fix the conductor
as shown on the chart.
- screw the cable clamp and fix the cover.
CONNECTION TO THE TERMINALS ON THE TERMINAL BLOCK: