TROUBLESHOOTING
PROBLEM
1 - Leaks from handle
2 - Insufficient flow rate
3 - Leak at connection points
4 - Loose faucet body
5 - Loose handle
PARTS LIST -
For any parts needed but not shown, please contact Vigo Technical Support
PART
Handle
Face Plate
Spout
Spout Rear Set Screws
Cartridge Housing
Spout Adapter
Cartridge Holder Ring
Spout Bottom Set Screws
Valve Housing
1.2 gpm flow restrictor
Cartridge
NSF / ANSI 61
\\192.168.10.252\todd$\certification logos\AB1953.jpg
POTENTIAL CAUSE
1.A - Cartridge unseated
1.B - Cartridge defective
2. - Clog in supply hose / line
2. - Clog in copper supply pins
3.A - Flexible hose leaking at connection point
3.B - Washer defective
4. - Mounting hardware became loose
5. - Set screw has become loose
PART #
SUPPLY DATE INDICATOR (INTERNAL USE ONLY)
68104
P
68101
P
68105
P
68106
P
68103
P
68099
P
68102
P
68107
P
68094
P
68108
P
74040
P
TOLL FREE: (866) 591 - 7792
E-Mail: techmail@vigoindustries.com
www.vigoindustries.com
CORRECTIVE ACTION
1.A - Remove cartridge from housing, wash thoroughly with hot
water and reseat in housing.
1.B - Contact Vigo Technical Support for replacement.
2. - Remove supply lines and flush lines.
2. - Remove copper pins and flush/clean out.
3.A - Tighten hoses. If this does not resolve the issue, remove
the flexible hose and rethread, checking to make sure the
connection is secure. Make sure to use pipe tape.
3.B - Remove supply line and check the status of the washer. If
torn, washer must be replaced for a secure, non-leaking
connection.
4. - From under the counter, use an adjustable wrench and
tighten the mounting hardware. Make sure the faucet is
perpendicular to the counter.
5. - Take off hot/cold cover on handle. This will give you access
to the screw that connects the handle to the cartridge. Using
either an allen key or a flat head screw driver, tighten the screw
so handle has firm connection to cartridge.
5