Step 1. Qualification
Ensure that the battery is in good condition prior to charge. Charger will not
be started if battery is less than 7.5V(12V system). If charger detect the
battery is slightly fatigue with minor sulphated condition, it will rejuvenate and
recover the battery back to its peak performance.
Step 2. Soft Start
Soft Start is used when the charger has detected a battery at a very low
initial state of charge. Voltage and current are delivered at specified rate to
help the battery to recover prior to entering Pulse mode.
Step 3. Pulse Mode
Detects sulphated batteries. Pulsing current and voltage removes sulphate
from the lead plates of the battery restoring the battery capacity.
Step 4. Recondition
Recondition follows when the pulse mode is completed, it aims to re-active
the element of battery for battery charging condition.
Step 5. Bulk
The normal charge is commenced to deliver the constant current for
charging up the battery until 80% full.
Step 6. Absorption
The charge program has switched over to constant voltage; the charge
current has to be reduced according to the raised of battery level, until the
battery is full.
Step 7. Full
The charge will stop until the battery is 100% charged.
Step 8. Analysis
It checks the battery voltage after charged, to make sure the voltage can be
EN-9