Transport, Storage, Packaging; Transport Inspection; Technical Data; Performance Data - oventrop Cocon QFC Instrucciones De Instalación Y Operación Para El Instalador Especializado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3 Transport, storage, packaging

3.1 Transport inspection

Upon receipt check delivery for any damages caused during
transit.
Any damage must be reported immediately upon receipt.
3.2 Storage
The pressure independent control valve "Cocon QFC/QGC"
must only be stored under the following conditions:
• Do not store in open air, but dry and free from dust.
• Do not expose to aggressive fluids or heat sources.
• Protect the valve from direct sunlight and mechanical
agitation.
• Storage temperature: -4 up to 131°F (-20 up to +55°C),
max. relative humidity of air: 95 %

4 Technical data

4.1 Performance data

Max. working temperature: 248 °F (120 °C)
Min. working temperature: 14 °F (-10 °C)
Max. working pressure:
1676149 - 1676156 232 psi (1600kPa)
1676251 - 1676253 232 psi (1600kPa)
1676351 - 1676353 362 psi (2500kPa)
Max. differential pressure: 58 psi (400kPa)
Fluid:
Water or Water/glycol
(max. 50%), ph-value 6.5-10
Item no.
Weight
DN
Size
[lbs]
PN 16
PN 25
1
1676149
40
1
"
2
1676150
50
2"
1
16761/6251
1676351
65
2
"
60/47
2
16761/6252
1676352
80
3"
71/58
16761/6253
1676353 100
4"
100/82
1676154
125
5"
157
1676155
150
6"
188
1676156
200
8"
331
* Recommended lowest setting; starting from the set value,
the flow rate can be reduced up to complete isolation.
Data for actuator connection:
DN 40/50
DN 65/80/100
Piston stroke
0.39" (10 mm) 0.79" (20 mm) 1.42" (36 mm) 1.57" (40 mm)
Closing
112.4 lbf
191,1 lbf
pressure
(500 N)
(850 N)
4.2 Materials
Cast iron body, seals made of EPDM or PTFE, inner parts
made of brass resistant to dezincification, maintenance-free
stem seal due to double O-ring, plastic parts made of PA6.
4.3 Dimensions / connection dimensions
4.3.1 "Cocon QFC"
Bolt circle for flanged connection according to ANSI 150.
2
Control range
Differential pressure
cvs
[GPM]
p1-p3
value
(min.*-max.)
(min.-max.)
22
6.6 - 33
13.3
29
8.8 - 35
13.9
22 - 90
41.6
33 - 130
64.7
2.9 psi - 58 psi
(20 kPa - 400 kPa)
55 - 220
92.5
119 - 468
173.4
158 - 660
254.3
242 - 837
312.1
DN 125
DN 150/200
449.6 lbf
449.6 lfb
(2000 N)
(2000 N)
L1
DN
L1
H
D
40
7.9
9.8
5
50
9.1
10.6
6
65
11.4
14.6
7.3
80
12.2
15.2
7.9
100
13.8
15.9
8.7
125
15.7
20.5
9.8
150
18.9
20.5
11.2
200
23.6
22.2
13.4
4.3.2 "Cocon QGC"
Groove connections for couplings
Suitable for couplings of the following systems:
- Victaulic
- Grinell
DN
L
65
11.42
80
12.20
100
13.78

5 Construction and function

5.1 Survey and functional description
The pressure independent control valve "Cocon QFC/QGC"
is a valve combination consisting of an automatic,
differential pressure independent flow regulator (with manual
nominal value setting) and a regulating valve. The regulating
valve can be equipped with an actuator.
K
n x Ød
3.9
4 x 0.6
4.8
4 x 0.7
5.5
4 x 0.7
6
4 x 0.7
7.5
8 x 0.7
8.5
8 x 0.9
9.5
8 x 0.9
11.8
8 x 0.9
D
H
2,87
7.3
3.50
7.9
4.50
8.7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cocon qgc

Tabla de contenido