Troubleshooting

Fault
No suction
output
(fumes/gases
are not being
extracted).
Suction output
too low
(fumes/gases
are hardly
being extracted).
APS is not
running.
HP Air Purifier System
Cause
Suction hose not connected
to the APS.
Suction hose not connected
to the machine
Damage to the suction
hose.
Suction hose is connected
to the wrong machine.
Suction hose is connected
to the wrong point of entry
(opening) of the machine.
Suction channel blocked.
Clean gas channel blo-
cked.
Filter elements full.
Damage to the suction
hose.
Suction hose not correctly
connected to the APS.
Suction hose not correctly
connected to the machine.
Air outlet blocked.
Suction hose is connected
to the wrong point of entry
(opening) on the machine.
Fault on the APS.
Plug connection power sup-
ply not or wrongly plugged
in.
No power on the socket.
Fault on the APS.
Correction
Connect suction hose to the APS.
Connect suction hose to the printer.
Replace suction hose.
Connect suction hose to the correct
machine.
Connect suction hose to the right point of
entry (opening) of the machine.
Check suction channel, if necessary cor-
rect error found.
Check clean gas channel, if necessary
correct error found.
Replace filter package, dispose of old fil-
ter properly!
Replace suction hose.
Check fitting of the suction hose to the
APS, if applicable reinsert into suction
opening.
Check fitting of the suction hose to the
machine if necessary reconnect.
Check air outlet status,and clean blocke
holes.
Connect suction hose to the right point of
entry (opening) on the machine.
Contact your HP Service representative.
Check/correctly plug in plug connection
power supply.
Check power supply, if necessary correct
error.
Contact your HP Service representative.