STORAGE

The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than 30 days,
use the following guidelines to prepare it for storage.

Generator Storage

• Clean the generator as outlined in "Generator Cleaning".
• Check that cooling air slots and openings on generator
are open and unobstructed.
WARNING
Storage covers can be flammable.
• DO NOT place a storage cover over a hot generator.
• Let equipment cool for a sufficient time before placing the
cover on the equipment.
Problem
No AC output is available, but
engine is running.
When loads are connected,
engine runs good but bogs down.
Engine shuts down during
operation.
Engine lacks power.

Engine Storage

See engine owner's manual for instructions.

Other Storage Tips

• To prevent gum from forming in fuel system or on
essential carburetor parts, add fuel stabilizer into fuel
tank and fill with fresh fuel. Run the unit for several
minutes to circulate the additive through the carburetor.
The unit and fuel can then be stored for up to
24 months. Fuel stabilizer can be purchased locally.
• DO NOT store fuel from one season to another unless
it has been treated as described above.
• Replace fuel container if it starts to rust. Rust and/or dirt
in fuel can cause problems if it's used with this unit.
• Store unit in a clean and dry area.
Cause
1.
Circuit breaker is open.
2.
Poor connection or defective
cord set.
3.
Connected device is bad.
4.
Fault in generator.
1.
Short circuit in a connected load.
2.
Generator is overloaded.
3.
Shorted generator circuit.
1.
Out of gasoline.
2.
Low oil level.
Load is too high.
13
Storage

Troubleshooting

Solution
1.
Reset circuit breaker.
2.
Check and repair.
3.
Connect another device that is in
good condition.
4.
Contact Authorized Service
Facility.
1.
Disconnect shorted electrical
load.
2.
See "Don't Overload Generator".
3.
Contact Authorized Service
Facility.
1.
Fill fuel tank.
2.
Fill crankcase to proper level or
place generator on level surface.
See "Don't Overload Generator".
Section
6
Section
7