TECHNICAL DATA
Important Note
It must absolutely be assured that the SAT accessories (LNC 's, multi-switch without own mains unit, etc.)
connected to one or two LNC inputs (F socket) do not exceed the maximum permissible current consumption of
350 mA. If the current consumption is > 350 mA, it is necessary to use a multi-switch with own power supply.
Reception parameters
Input frequency:
Input impedance:
IF bandwidth:
Static threshold:
Bandwidth reduction:
Audio
Frequency range:
Audio modes:
Audio bandwidth:
Audio deemphasis:
Video
Video deviation:
Video polarity
Baseband:
LNC control
LNC power supply:
LNC frequency:
LNC switching signal:
DiSEqC:
Connector:
The unit conforms to the protection requirements set out in the EC directives 73/23/EEC
and 89/336/EEC. Standards EN 55013/A12, EN 55020 and EN 60065, as required for the CE
certification, have been complied with.
_______________________________________________________________
950 to 2150 MHz
75 Ohm
27 MHz
6 dB
3-stage
5.00 to 9.00 MHz
mono / stereo (Wegener licence)
130 / 180 / 280 / 380 / 480
50 µsec. / J17/ Panda selectable
16 MHz, 22.5 MHz, 25 MHz selectable
positive/ negative
linear / PAL
0 / 14 / 18V, max. 350 mA
according to system, max. 8 frequencies selectable
22 kHz
off/ MiniDiSEqC / DiSEqC 1.0
1 F socket