EM3xx Technical specifications
Power supply
Current draw in standby status
Current draw in alarm status
Input balancing resistance
Alarm input resistance
Supervised output EOL resistance
Relay contact rating
Operating temperature
Humidity (without condensation)
Height (with terminal boards)
Height (without anchor locations)
Width
Depth (with terminal boards)
Depth (without terminal boards)
Weight (with terminal boards)
Testing and maintenance
The functionality of the module should be tested immediately
after
installation
and
inspections, in accordance with the established standard
regulations and codes in force.
Using the EITK-DRV driver
The EITK-DRV driver allows you to change the operating
parameters of the devices connected to the loop and also to
obtain accurate diagnostic data. It can operate through the USB
port of a computer furnished with the relative software
programme, or can function autonomously by way of the battery
housed inside.
For further information and details regarding use of the EITK-DRV
driver, refer to the respective handbook.
Warnings and limitations
The EM3xx module must be used exclusively with control panels
that operate on INIM OpenLoop protocol. This product is not
suitable for outdoor installation. However, if outdoor installation
is necessary, ensure that the device is housed inside a suitable
enclosure with the required protection grade.
CE marking and certifications
DoP, EC DoC and certificates related to these products can be
downloaded from the following link:
www.inim.biz/certifications
INIM Electronics reserves the right to change the technical
specifications of this product without prior notice.
8
19-30 Vdc
Max 80μA @ 24V
20 mA @27.6V
22K Ohm
2,2K Ohm
22K Ohm
MAX 1A / 30Vdc
-5°C/+40°C
95% RH
106 mm
99 mm
113 mm
29 mm
19 mm
140 g
periodically
during
Short-circuit isolator Technical specifications
V
The maximum line voltage
max
V
The nominal line voltage
nom
V
The minimum line voltage
min
The maximum voltage at which the
V
SO max
(i.e. switches from closed to open)
The minimum voltage at which the
V
SO min
(i.e. switches from closed to open)
The maximum voltage at which the
V
SC max
(i.e. switches from open to closed)
The maximum leakage current with the
I
L max
The maximum rated switching current
I
c max
(e.g. with the switch closed)
The maximum rated continuous current
I
S max
(e.g. under short circuit conditions)
The maximum series impedance with
Z
C max
maintenance
Intellingent analogue addressable multi input/output module
with short-circuit isolator for fire detection and fire alarm
Via Dei Lavoratori 10 - Fraz. Centobuchi
63076 Monteprandone (AP) - Italy
www.inim.biz info@inim.biz
device isolates
device isolates
device reconnects
switch open
(isolated state)
the switch closed
systems installed in buildings
INIM ELECTRONICS S.R.L.
Tel. +39 0735 70 50 07
Fax + 39 0735 70 49 12
EM3xx
30 Vdc
24 Vdc
19 Vdc
12.5 Vdc
10 Vdc
9 Vdc
15 mA
600 mA
600 mA
0.5 mOhm