ENGLISH

1

PRODUCT DESCRIPTION

The control box for boom end nozzle with Seletron is an electric device which allows manual and
independent management of two nozzle holders with Seletron electric valve.
The control box must be connected only to ARAG Seletron electric valves.
1.1

Intended use

This device has been designed for installation on agricultural machinery for crop spraying
and spraying applications.
2
PRECAUTIONS
- Never expose the equipment to water jets.
- Never use solvents or petrol to clean the external parts of the container.
- Comply with the specific power supply voltage (12 Vdc).
- In case of electric arc welding, make sure that the power supply to the device is discon-
nected; if necessary, disconnect the power supply cables.
- Use only original ARAG spare parts or accessories.
3
INSTALLATION
3.1
Fitting the control box (Fig. 1)
1) Fasten gatebracket with screws.
2) Push the control box into the gatebracket up to block it.
3.2
Connecting the control box to power supply (Fig. 2)
Please refer to the diagram in Fig. 2 for the correct connection to the power supply.
3.3
Control box connection to Seletron devices (Fig. 3)
For the connection to the two Seletron nozzle holders, use the suitable cable (Code 46685204.110,
to be ordered separately).
IMPORTANT:
The control box is equipped with an internal self-resetting safety device that cuts the
power in case of operational defects or problems.
If the safety device starts up, all the warning lights on the box go out, but since no other
signal is provided for, the operator must pay attention that the box is still active and that
when a command is selected on the box the action is performed by the system (Fig. 4).
If the control box goes off due to the safety device and the operator wishes to stop
spraying (if in operation), he must do so by acting on the pump.
If the internal safety device starts up, it is necessary to remove power from the box (by
turning off the tractor) and wait at least 20 seconds before restarting. Should the problem
persist, contact the nearest Assistance Centre.