EN
WARNINGS
• The OKSOL solar DHW system must be assembled by an authorized installer.
• Do not install the OKSOL unit on a flat or inclined surface without following the general safety
regulations.
• The installer must ensure that all materials are delivered in good condition.
• Prior to assembly, the installer shall ensure that neither the substructure, anchor surfaces nor the stability
of the building will be compromised by the additional load the unit adds according to the regulations.
• Installers must ensure that fastenings to the surface in the form of anchors, plugs, or screws are suitable
for existing concrete, wood, sandwich panels, etc. used in the building.
• Installers must ensure that profiles installed that are not in our catalogue can support the applied static
and live loads and meet regulations in force in each country.
• For loading conditions not covered by the document, please contact technical support.
• Permissible applications (with accumulator full):
• The OKSOL system does not have to be installed in peripheral areas of the roof (peripheral areas e/10
based on EN 1991 standard, the minimum distance being 1 m.).
16
1,53 (standard load)
3,06 (maximum load)
(kN/m
2
)
20º - 50º
140
(km/h)