Features; Technical Data; Start-Up - ADE WS 1501 Manual De Instrucciones

Ocultar thumbs Ver también para WS 1501:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
2.

Features

-
Extra large LCD
-
Internal room temperature indicator
-
Dew point temperature indicator
-
Display of relative humidity indoors
-
Selectable temperature indicator, in °C or °F
-
Max/min indicator of temperature and relative humidity
-
Graphical display of relative humidity over the last 12 hours
-
Mould alert with warning symbol and blinking LED alarm signal, as well as
selectable threshold values (60%, 65%, 70%, 75%)
-
Humidity alarm with warning symbol and blinking LED alarm signal, as well as
programmable threshold values for the upper/lower relative humidity (30 - 95%
in 5% intervals)
-
Easy-to-read, colour comfort index (comfort level)
-
Operation by means of sensor buttons
3.

Technical Data

-
Temperature indicator
-
Dew point temperature range
-
Tolerance
-
Relative humidity range
-
Tolerance
-
Temperature resolution
-
Relative humidity resolution
-
Temperature outside the permissible range:
Dew point temperature outside the permissible range:
-
4.

Start-up

Open the battery compartment on the back of the thermometer/hygrometer, insert
the supplied batteries (2 x 1.5V AAA) and then close the battery compartment
again. Please be mindful of the correct polarity of the batteries (+/-). The
thermometer/hygrometer is now ready.
Setting the humidity alarm
1. In order to activate the humidity alarm, press and hold the SET button until
the ALERT and
display and the humidity indicator blinks. Now press the
order to set (in 5% intervals) the upper humidity threshold.
symbols appear simultaneously in the upper part of the
3
0 °C to +50 °C
0 °C to +50 °C
+/- 1 °C
20% to 95%
+/- 5%
0.1 °C
1%
HH.H/LL.L
HH.H/LL.L
or
button in

Publicidad

Tabla de contenido
loading

Tabla de contenido