MAINTENANCE
SEASONAL MAINTENANCE
(by the TAC - technical assistance centre)
• General cleaning, inside and out
• Accurate cleaning of the exchange pipes inside the hot air output grill located in the upper part of the front of the stove
• thorough cleaning and removing encrustation of the crucible and the relative chamber
• Cleaning of the smoke extractor fan, mechanical check on play and fixings
• Cleaning of the flue (replacement of the gasket on the flue pipe)
• Cleaning of the smoke duct
• Cleaning of the smoke extractor fan, cleaning of the pressure switch, check on the thermocouple.
• Cleaning, inspection and removal of encrustations on the ignition resistance chamber, replacement of the same if necessary
• Cleaning/check of the synoptic panel
• Visual inspection of the electric wires, of the connections and of the power-supply wire
• Cleaning of the pellet hopper and check on play of the screw-gear motor group
• Replacement of the door gasket
• Test of functioning, screw loading, ignition, operation for 10 minutes and switching off.
If the stove is used very frequently, it is advisable to clean the flue every 3 months.
ATTENTION!!
After normal cleaning, INCORRECT attachment of the upper part of the crucible (A) (fig. 1) with the lower part of the
crucible (B) (fig. 1) can compromise stove functioning.
Therefore, before igniting the stove, make sure that the two parts of the crucible are correctly attached as indicated in (fig.
2) without any ash or unburnt fuel on the contact edges.
We remind you that using the stove without cleaning the melting pot, may cause a sudden ignition gas inside the combus-
tion chamber with the consequent breaking of the glass
A
B
fig. 1
fig. 2