Work Area Safety; Electrical Safety; Personal Safety - DeWalt DCH733 Traducido De Las Instrucciones Originales

Ocultar thumbs Ver también para DCH733:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40
*Date code 201811475B or later
**Date code 201536 or later
EnGLIsh
Batteries
Cat #
V
DC
DCB546
18/54
DCB547
18/54
DCB548
18/54
12.0/4.0
DCB181
18
DCB182
18
DCB183/B
18
DCB184/B
18
DCB185
18
DCB187
18
DCB189
18
*Date code 201811475B or later
**Date code 201536 or later
NOTICE: Indicates a practice not related to
personal injury which, if not avoided, may result in
property damage.

Denotes risk of electric shock.

Denotes risk of fire.
GENERAL POWER TOOL SAFETY WARNINGS

WARNING: Read all safety warnings, instructions,
illustrations and specifications provided with this
power tool. Failure to follow all instructions listed below
may result in electric shock, fire and/or serious injury.
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE.
The term "power tool" in the warnings refers to your mains-
operated (corded) power tool or battery-operated (cordless)
power tool.

1) Work Area Safety

a ) Keep work area clean and well lit. Cluttered or dark
areas invite accidents.
b ) Do not operate power tools in explosive
atmospheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks which
may ignite the dust or fumes.
c ) Keep children and bystanders away while operating
a power tool. Distractions can cause you to lose control.

2) Electrical Safety

a ) Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any adapter
plugs with earthed (grounded) power tools.
Unmodified plugs and matching outlets will reduce risk of
electric shock.
b ) Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric shock if
your body is earthed or grounded.
28
Weight (kg) DCB104
DCB107
Ah
6.0/2.0
1.05
60
9.0/3.0
1.46
75*
1.44
120
1.5
0.35
22
4.0
0.61
60/40**
2.0
0.40
30
5.0
0.62
75/50**
1.3
0.35
22
3.0
0.54
45
4.0
0.54
60
Chargers/Charge Times (Minutes)
DCB112
DCB113
DCB115
270
170
140
90
420
270
220
135*
540
350
300
180
70
45
35
22
185
120
100
60
90
60
50
30
240
150
120
75
60
40
30
22
140
90
70
45
185
120
100
60
c ) Do not expose power tools to rain or wet conditions.
Water entering a power tool will increase the risk of
electric shock.
d ) Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool. Keep
cord away from heat, oil, sharp edges or moving
parts. Damaged or entangled cords increase the risk of
electric shock.
e ) When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
f ) If operating a power tool in a damp location is
unavoidable, use a residual current device (RCD)
protected supply. Use of an RCD reduces the risk of
electric shock.

3) Personal Safety

a ) Stay alert, watch what you are doing and use
common sense when operating a power tool. Do not
use a power tool while you are tired or under the
influence of drugs, alcohol or medication. A moment
of inattention while operating power tools may result in
serious personal injury.
b ) Use personal protective equipment. Always wear eye
protection. Protective equipment such as a dust mask,
non-skid safety shoes, hard hat or hearing protection used
for appropriate conditions will reduce personal injuries.
c ) Prevent unintentional starting. Ensure the switch
is in the off-position before connecting to power
source and/or battery pack, picking up or carrying
the tool. Carrying power tools with your finger on the
switch or energising power tools that have the switch on
invites accidents.
d ) Remove any adjusting key or wrench before turning
the power tool on. A wrench or a key left attached
to a rotating part of the power tool may result in
personal injury.
e ) Do not overreach. Keep proper footing and balance
at all times. This enables better control of the power tool
in unexpected situations.
DCB118
DCB132
DCB119
60
90
X
75*
135*
X
120
180
X
22
22
45
60/40**
60
120
30
30
60
75/50**
75
150
22
22
X
45
45
90
60
60
120

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dch773

Tabla de contenido