Descargar Imprimir esta página

NA-DE 10800 Manual Del Usuario página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

TS EN 60669-2-1
TS EN 60598-2-1
Complies with ROHS Regulation Directive
2002/95/EC
10800-10810
e-MOTION WALL-LIGHT WITH 180° MOTION SENSOR
USAGE AREAS
• At the building entrances, stair vestibules.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.
"OFFERS ENERGY SAVING FEATURE''
GENERAL SECURITY CAUTIONS
• Take off the original package and control if there is any damage of transportation
and general view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist
electricians must install and apply.
CAUTIONS FOR INSTALLATION AND USAGE
• Installing must be carried out professionally in accordance with applicable national
wiring and electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Fix the bulb before operating.
• Use 6A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting
of the time and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you
need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And
that you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the glass, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes
such as heaters, fans, refrigerators and ovents etc, and prevent the detector from
point-blank sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the
coverage area.
SPECIFICATIONS
Operating voltage
: 230-240V~ 50/60 Hz
Angle of coverage
: 180°
Detection hight
: 2.2 m.
Detectio range
: 3-12 m
Time adjustement
: 10 sec. ± 1 sec. / 5 min. ± 10 sec.
Lighting load
: Max 1x60W E27 Bulb
Protection class
: IP43 - Class II
Opt. temperature
: -20 °C ~ +40°C
Detection range is determined at the temperature of +20°C
SETTING
TIME
LUX
SENSE
(LUX) Daylight setting
The sensor's response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob anti-clockwise device will operate at dark.
Control dial set clockwise
= daylight operation approx. 2000 lux.
Control dial set anti clockwise = night-time operation approx. 2 lux.
(TIME) (f) Time setting
Light ON time can be adjusted continuously from
"10 sec. ± 1 sec. / 5 min. ± 10 sec." If you turn the knob anti-clockwise device
will operate at minimum time. (10 seconds)
Control dial set to anticlockwise = Shortest time (10 sec. ± 1 sec.)
Control dial set to clockwise= Longest time (5 min. ± 10 sec.)
(SENSE) Detection Range Setting
SENSE adjustment is used to set the detection range. For optimum range, please
set the knob to middle point. For maximum range (12 m) please turn clockwise,
for minimum range (3 m) turn anti-clockwise.
NOTE: Device will automatically make its own offset by checking environment
for approximately 5 minutes after the first installation. After this period device will
operate normally. If you think the device does not operate normal in first installation,
please wait for 5 minutes and start to test again. Be sure that there is no motion
by this period.
DETECTING RANGE
(a) Body
(b) Wall mounting hole
(c) Terminals
(d) Lamp-holder
(e) plastic part of angel
(f) Cable hole
(g) Screw of fix to glass
(h) Glass
10800-10810
info@na-de.com.tr • www.na-de.com.tr
(L) = Line conductor
(N) = Neutral conductor
(L') = Protective earth conductor
Connect line (L) and neutral (N) to the terminal block.
The bulb must be fixed before the electrical connection.
12 m.
24 m.
SYSTEM COMPONENTS
(a)
(b)
(g)
Mounting figure a part to the wall surface by in figure b holes with screw as a paralle to
wall
TROUBLESHOOTING
MALFUNCTION
CAUSE
• Lamp is off
• Daylight adjustment set to
night-time mode during daytime
operate
• Bulb faulty or there is no
connection
• Power switch off or no electricity
• Fuse faulty
• There is no
• Fuse switch off or fuse faulty
electricity on the
device
• Connection faulty.
• Continuously
• Continuously movement in
lamp is on
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.
• Change
• Sudden temperature changes due
perception
to weather(wind, rain, snow) or the
area in device
air expelled from fans.
• Different ambient temperatures.
DETECTION AREA :
Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature (power of lamps changes this temperature), mounting style and mounting
place. Temperature is very important for operation for motion sensor like all electronic devices.
Using higher value of loads written on manuals and packages will decrease temprature inside
the device when using Na-De Ceiling Armatures with Motion Sensor. As a result detection range
will decrease and may cause defect of electronic components. Environment temperature will
also cause decrease of detection range. Detection range give is determined at +20°C. If the
weather is hot, it will decrease.
Walking targential to the sensor
(normal detection range)
The maximum detection range can be realized when walking tangential to the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able
to cut vertical areas. Detection range of 10800 and 10810 models is 12 m.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded. Claims under the warranty will only be
accepted if the unit is sent fully assembled and well packed complete with a brief description
of the fault, a receipt or invoice ( date of purchase and dealer's stamp) to the appropriate
Service Center.
12 m.
12 m.
(h)
(f)
(d)
(g)
(b)
(c)
(e)
SOLUTION
• Control daylight setting and
re-adjust
• Fit the bulp into the lamp holder,
if it still does not operate, change
the bulb.
• Check the electricity and power on.
• Change the fuse.
• Check the fuse if necessary use
a new fuse.
• Check the connection cables.
• Check the detection zone.
• Avert it is being detection.
• Change detection zone, change
site of installation.
• Change site of installation or
keep the reasons away.
• Change site of installation.
Walking directly to the sensor
(lower detection range)
Figure 1
KK-10800/810_150416_TR_EN_00

Publicidad

loading

Este manual también es adecuado para:

10810