4.
The case temperature becomes hot (exceeds 145°F).
Solution: Allow the inverter to cool. Do not block the cooling
slots or air flow over and through the inverter. Reduce the
load on the inverter to the continuous rated output.
RESET: To reset after shutdown occurs, remove the 12-volt plug
from the accessory outlet. Check the source of the problem and
correct. Reinsert the 12-volt plug into the accessory outlet.
7.

IF THE INVERTER FUSE BLOWS

Your power inverter is fitted with a fuse, which should not have
to be replaced under normal operating conditions. A blown fuse
is usually caused by reverse polarity or a short circuit within the
device or equipment being operated.
If the fuse does blow:
1.
Disconnect the device or equipment immediately.
2.
Find the source of the problem, and repair it.
3.
Install a new fuse, 15-amp. The fuse can be found on the
end of the plug on the inverter.
4.
Do not tighten the fuse cap too tight; finger tight is sufficient.
may damage the inverter. Make sure to correct the cause of the
blown fuse before using the inverter again.
8.

TROUBLESHOOTING

PROBLEM
LEDs do not light,
or inverter does not
function.
Do not install a fuse higher than 15-amp, as this
REASON
Poor contact at
terminals.
Fuse Blown.
Inverter shutdown.
Inverter may not be
working properly.
• 6 •
SOLUTION
Unplug and reinsert the
12-volt plug.
See "IF THE INVERTER
FUSE BLOWS" section.
See "LED INDICATOR
AND SHUTDOWN
PROTECTION" section.
See Warranty and call
Customer Service 1-800-
621-5485 (Hours: 7:00
am – 5:00 pm CST).