Descargar Imprimir esta página

Jasco ZW4002 Guia De Inicio Rapido

Interruptor de pared inteligente para el control de ventiladores

Publicidad

Enlaces rápidos

FCC/IC
En
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS
standards. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from which the receiver is
connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change
to the antenna or the device is permitted. Any change to the antenna or the device could result
in the device exceeding the RF exposure requirements and void user's authority to operate
the device.
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils
exempts de licence d'Industrie Canada. Son utilisation est sujette aux deux conditions
suivantes : (1) cet appareil ne doit pas occasionner de brouillage préjudiciable et (2) cet
appareil doit accepter toutes les interférences reçues, notamment les interférences qui
peuvent provoquer un fonctionnement non désiré.
NOTE DE LA FCC : Le fabricant n'est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées
de ce matériel. De telles modifications peuvent annuler le droit de l'utilisateur à utiliser cet
appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites
ont été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable
en milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence
radio et, s'il n'est pas installé et utilisé conformément aux instructions, il peut provoquer un
brouillage préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que
des interférences ne se produiront pas au sein d'une installation donnée. Si cet appareil
occasionne un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit
d'allumer et d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons
l'utilisateur à essayer de corriger ces interférences en appliquant une ou plusieurs des
mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC
concernant l'exposition aux RF, aucune modification apportée à l'antenne ou au dispositif n'est
autorisée. Toute modification apportée à l'antenne ou au dispositif pourrait faire en sorte que le
dispositif dépasse les exigences d'exposition aux RF et pourrait annuler le droit de l'utilisateur
à utiliser ce dispositif.
Es
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC
y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria
de Canadá aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las
siguientes dos condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y (2)
este dispositivo debe aceptar toda interferencia que reciba, incluso la que pudiera causar un
funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio
o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas
modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de
Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos límites están
diseñados para proveer protección razonable contra interferencias perjudiciales en una
instalación residencial. Este equipo genera, usa y puede irradiar energía de radiofrecuencias
y, si no se instala y usa según las instrucciones, puede provocar interferencia perjudicial a
las radiocomunicaciones. No obstante, no hay garantías de que no ocurrirá interferencia en
una instalación en particular. Si este equipo provoca interferencia perjudicial a la recepción
de radio o televisión, lo que puede determinarse encendiendo y apagando el equipo, se
recomienda que el usuario intente corregir la interferencia por medio de la implementación de
una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que está
conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
Responsible Party - US Contact Information | Parte responsable - Informaór Estados
Unidos | Partie responsable - Coordonnées des États-Unis
FCC — U2ZZW4002A | IC: 6924A-ZW4002A
Jasco Products Company | Model: ZW4002/55259
10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
All brand names shown are trademarks of their
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
respective owners.
DISTRIBUTED BY
Tous les noms de marque illustrés sont des marques
JASCO PRODUCTS COMPANY LLC,
de commerce de leurs propriétaires respectifs.
10 E. MEMORIAL RD.,
Todas las marcas que aparecen aquí son marcas
OKLAHOMA CITY, OK 73114.
registradas de sus respectivos dueños.
©JASCO 2020 | ZW4002 | 55259 | 08/03/20 v1
1.
1.
Tools you will need
IMPORTANT!
No more than two identical fans to the smart switch. Not to exceed 2.5A resistive
load. CONTROLS FAN MOTOR ONLY. For use only with split-capacitor or
shaded-pole ceiling fan motors.
Getting to know your new Z-Wave device
• Turn ON/OFF and adjust fan speed levels manually or remotely via the
Z-Wave controller
• Can be included in multiple groups and scenes
• May be used in single-pole installation or with up to two Jasco add-on switches in
3-way or 4-way wiring configurations
• Interchangeable paddle switch — white & light almond paddle in package
• Uses a standard, rocker-style wallplate for single-gang installations
(wallplate not included)
• Blue LED indicates switch location in a dark room
• Z-Wave certified for simple pairing and integrated home automation
• Screw terminal installation — requires wiring connections for line (hot), load,
neutral and ground. Traveler wire required for 3-way or 4-way installation
• This Z-Wave device has advanced features that allow you to customize your
experience. These features can only be adjusted by a Z-Wave enabled controller
that supports the Z-Wave configuration command class. For a complete list of
adjustable configurations, visit www.ezzwave.com/config
NOTE: This smart device only controls the fan motor and does not control any lighting
connected to the fan. If your fan has an integrated light, a second switch must be installed
to control the lighting directly. No more than two identical fans should be connected to the
fan control. The total load of the fan(s) should not exceed 2.5A.
2.
2.
A
F
B
D
G
C
E
A. Ground (Green/Bare)
F. Top rocker — press & release
to turn fan on, press & hold to
B. Load (Black)
increases speed
C. Line (Black)
G. Bottom rocker — press &
release to turn fan off, press &
D. Traveler (Red/Other)
hold to decrease speed
E. Neutral (White)
Multiple-gang boxes
When installing the smart fan control in multiple-gang boxes, it may be
necessary to break off one or both sides of the scored tabs on the front yoke.
This does not affect the electrical rating of the switch (see specifications for details).
MANUAL • MANUEL •
MANUAL
READ IT OR WATCH IT
In-Wall
Smart Fan Control
intelligent
Montage mural
commande de ventilateur
Read instructions or watch easy-to-follow video.
Scan QR code or visit https://byjasco.com/55259i
Interruptor de pared
inteligente para el control
de ventiladores
Purchase additional items at
EZzwave.com or visit your local retailer.
In-Wall
In-Wall
Plug-in
Smart Dimmers
Smart Dimmers
Add-on Switches
In-Wall Motion
In-Wall
Plug-in
Switch or Dimmer
Smart Switches
Smart Switches
In-Wall
Enbrighten
Hinge Pin
Smart Fan Control
Smart LED Bulb
Smart Door Sensor
Direct Wire,
Portable
In-Wall
40A Outdoor
Tamper-Resistant
Outdoor Smart
Smart Multi
Smart Outlet
Smart Switch
Sensor
3.
3.
OR
OR
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and fixture at the service
panel. All wiring connections must be made with the POWER OFF to avoid personal
injury and/or damage to the switch. This device is intended for installation in
accordance with the National Electric Code and local regulations in the United States,
or the Canadian Electrical Code and local regulations in Canada. If you are unsure or
uncomfortable about performing this installation, consult a qualified electrician.
Multi-switch wiring
For 3-way installations, please refer to add-on switch manual.
Single-switch wiring
Before installation, you may wish to change the paddle color to match your wallplate or décor.
Please proceed to section 5.
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wallplate.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
5. There are five screw terminals on the fan control; these are marked:
A. GROUND – Green/Bare
B. LOAD – Black (connected to fan)
C. LINE (Hot) – Black (connected to power)
D. TRAVELER – Red/Other (only in 3-way installations)
E. NEUTRAL – White
4.
4.
Adding your device to a Z-Wave network
To remove and reset the device
1. Follow the instructions for your Z-Wave certified controller to add a
1. Follow the instructions for your Z-Wave certified controller to
device to the Z-Wave network.
2. Once the controller is ready to add your device, press the top or
2. Once the controller is ready to remove your device, press and
bottom rocker of the fan control.
You have complete control to turn your fan ON/OFF and adjust speed
To return your switch to factory defaults
according to groups, scenes, schedules and interactive automations
programmed by your controller.
Quickly press ON (top) button three times. Then, immediately press
If your Z-Wave certified controller features remote access, you can
the OFF (bottom) button three times. The LED flashes ON/OFF five
control your fixture from your mobile devices.
times when completed successfully.
If prompted by the controller to enter the S2 security code, refer to the
NOTE: This should only be used in the event your network's primary
Verify this product supports S2/SmartStart QR code/security number
controller is missing or otherwise inoperable.
on the side of the box or the QR code label on the product (see Figure
1). Enter the 5-digit pin code.
NOTE: SmartStart enabled products can be added into a Z-Wave
network by scanning the QR code on the product with a controller
Figure 1.
providing SmartStart inclusion. No further action is required and the
DSK :
Z-WAVE DSK
XXXXX
SmartStart product will be added automatically within 10 minutes of
-25651-22671
being switched on in the network vicinity.
-26939-47599
-19612-25872
PIN: XXXXX
-47752
DO NOT RETURN THIS
PRODUCT TO THE STORE
NE RETOURNEZ PAS
STOP
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
If you have any problems or questions, contact our U.S.-based Consumer Care at
1-800-654-8483, option 1, Monday–Friday, 7AM–8PM Central Time.
For the most up-to-date product support, accessories, electronic (PDF) format
manuals and more, visit www.byjasco.com/support.
• No user-serviceable parts in this unit.
Si vous avez des problèmes ou des questions, veuillez communiquer avec notre
service à la clientèle aux États-Unis au 1-800-654-8483, option 1, du lundi au
55259
vendredi, de 7 h à 20 h, heure du Centre.
ZW4002
Pour le soutien relatif aux produits le plus à jour, les accessoires, les manuels en
format électronique (PDF) et plus encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro Centro de atención al
cliente con sede en EE. UU. al 1-800-654-8483, opción 1 de lunes a viernes, de 7
a.m. a 8 p.m., hora del Centro.
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
ADVERTENCIA
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
CONTROLLING APPLIANCES:
CONTROL DE APARATOS:
CONTROL FAN MOTOR ONLY (FOR USE ONLY WITH
CONTROLAR SOLO EL MOTOR DEL VENTILADOR
SPLIT-CAPACITOR OR SHADED-POLE CEILING FAN
(PARA USAR SOLO CON MOTORES DE
MOTORS).
VENTILADOR DE TECHO CON CONDENSADOR
DIVIDIDO O POLO SOMBREADO).
• DO NOT USE Z-WAVE DEVICES TO CONTROL
ELECTRIC HEATERS OR ANY OTHER APPLIANCES
• NO USAR LOS DISPOSITIVOS Z-WAVE PARA
WHICH MAY PRESENT A HAZARDOUS CONDITION
CONTROLAR CALENTADORES ELÉCTRICOS U
DUE TO UNATTENDED OR UNINTENTIONAL OR
OTROS APARATOS ELECTRODOMÉSTICOS QUE
AUTOMATIC POWER ON CONTROL.
PUDIERAN IMPLICAR UN PELIGRO DEBIDO A UN
ENCENDIDO SIN SUPERVISIÓN, ACCIDENTAL O
AUTOMÁTICO.
AVERTISSEMENT
RISQUE D'INCENDIE
NOT FOR USE WITH MEDICAL OR
RISQUE DE CHOC ÉLECTRIQUE
LIFE-SUPPORT EQUIPMENT
RISQUE DE BRÛLURES
Z-WAVE ENABLED DEVICES SHOULD
NEVER BE USED TO SUPPLY POWER TO
OR CONTROL THE ON/OFF STATUS OF
COMMANDE DES APPAREILS :
SOYEZ TRÈS PRUDENT LORSQUE VOUS UTILISEZ
MEDICAL OR LIFE-SUPPORT EQUIPMENT.
MOTEUR DE VENTILATEUR DE COMMANDE
UNIQUEMENT (À UTILISER UNIQUEMENT AVEC
NE PAS UTILISER AVEC UN ÉQUIPEMENT
DES MOTEURS DE VENTILATEUR DE PLAFOND À
MÉDICAL OU DE SURVIE
CONDENSATEUR DIVISÉ OU À PÔLES OMBRÉS).
LES DISPOSITIFS COMPATIBLES AVEC LA
• N'UTILISEZ PAS LES DISPOSITIFS Z-WAVE
TECHNOLOGIE Z-WAVE NE DEVRAIENT
POUR COMMANDER LES RADIATEURS
JAMAIS ÊTRE UTILISÉS POUR ALIMENTER OU
ÉLECTRIQUES OU D'AUTRES APPAREILS QUI
COMMANDER LA MISE EN MARCHE OU L'ARRÊT
DE L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
POURRAIENT PRÉSENTER UN DANGER EN
CAS DE COMMANDE D'ACTIVATION IMPRÉVUE,
INVOLONTAIRE OU AUTOMATIQUE.
SE PROHÍBE SU EMPLEO EN EQUIPO MÉDICO
O EQUIPO PARA EL MANTENIMIENTO
DE LAS FUNCIONES VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN
USAR PARA SUMINISTRAR ENERGÍA ELÉCTRICA
AL EQUIPO MÉDICO O AL EQUIPO PARA EL
MANTENIMIENTO DE FUNCIONES VITALES, NI
PARA CONTROLAR EL ESTADO DE ENCENDIDO
O APAGADO DE DICHOS EQUIPOS.
Plug-in
Switch
Insert wires into holes, do not wrap wires around
screws.
Do not remove screws.
Out to Light (Load)
B
D
E
A
C
From Breaker Box
6. Match these screw terminals to the wires connected to the existing switch.
7. Disconnect the wires from the existing switch. Label wires according to the previous
terminal connections.
Observe important wiring information
IMPORTANT! This fan control is rated for and intended to only be used with copper wire.
Wire gauge requirements
Use 14AWG or larger wires suitable for at least 80
C for supplying line (hot), load, neutral, ground
°
and traveler connections.
Wire strip length
1. For attachment using the enclosure's holes, strip insulation 5/8in. (16mm).
UL specifies the tightening torque for the screws is 14Kgf-cm (12lbf-in.).
2. Connect the green or bare copper ground wire to the GROUND terminal.
4. Connect the black wire from the fan to the LOAD terminal.
4. Connect the black wire from the electrical service panel (hot) to the LINE terminal.
5. Connect the white wire to the NEUTRAL terminal (use jumper wire if needed).
The traveler terminal is only used for 3-way or 4-way wiring and should remain unused if
NOTE:
the fan control is installed in a 2-way system (one switch & one load).
6. Insert fan control into the switch box being careful not to pinch or crush wires.
7. Secure the fan control to the box using the supplied screws.
8. Mount the wallplate.
9. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic operation
Before starting, fan must be set to HIGH position using pull chain.
NOTE:
The connected fan can then be turned ON/OFF and adjust speed levels in two ways:
1. Manually from the front panel of the fan control.
2. Remotely with a Z-Wave controller.
5.
5.
remove a device from the Z-Wave network.
release the top or bottom rocker of the fan control.
The Jasco add-on switch is required for
multi-switch 3-way or 4-way installations.
Connecting the traveler terminal of this switch
to a standard, non-Jasco switch will cause
damage or result in improper function. If this
switch is part of a multi-switch installation, do
not connect the traveler wire or apply power
until Jasco add-on switches are correctly
installed. For more information on multi-switch
installations, view the Jasco add-on switch
manual.
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects for five years
from the original date of consumer purchase. This warranty is limited to the repair or replacement of this
product only and does not extend to consequential or incidental damage to other products that may be
used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states
do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of
incidental or consequential damage, so the above limitations may not apply to you. This warranty gives
you specific rights, and you may also have other rights which vary from state to state. Please contact
our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM – 8PM, M-F, Central Time
or www.byjasco.com if the unit should prove defective within the warranty period.
GARANTIE
Jasco Products Company garantit que ce produit est exempt de tout défaut de fabrication pour
une période de cinq ans à compter de la date de l'achat original par l'acheteur. Cette garantie se
limite exclusivement à la réparation ou au remplacement de ce produit et n'est pas applicable aux
dommages indirects ou accessoires survenus sur d'autres produits utilisés avec ce produit. Cette
garantie se substitue à toute autre garantie expresse ou implicite. Certains États ne permettent pas
de restrictions quant à la durée d'une garantie implicite ou permettent l'exclusion ou la limitation des
dommages indirects et accessoires; il se peut, par conséquent, que cette garantie ne s'applique pas
dans votre cas. Cette garantie vous confère des droits juridiques précis; vous pouvez jouir d'autres
droits qui peuvent varier d'un État à l'autre. Veuillez communiquer avec notre service à la clientèle aux
États-Unis au 1-800-654-8483 (option 1) entre 7 h et 20 h, heure du Centre ou par l'intermédiaire de
notre site web www.byjasco.com si l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
Jasco Products Company garantiza que este producto está libre de defectos de fabricación durante un
periodo de cinco años a partir de la fecha original de compra por parte del consumidor. Esta garantía
se limita a la reparación o reposición de este producto y no cubre daños indirectos o incidentales a
otros productos que se pudieran utilizar con este producto. Esta garantía reemplaza cualquier otra
garantía explícita o implícita. Algunos estados no permiten la aplicación de limitaciones respecto de
la duración de una garantía implícita o permiten la exclusión o limitación de la cláusula sobre daños
indirectos o incidentales, por este motivo las limitaciones arriba mencionadas pueden no aplicarse
en su caso. Esta garantía le otorga derechos específicos y es posible que tenga otros derechos que
pueden variar según el estado en el que vive. Por favor, comuníquese con nuestro Centro de atención
al cliente con sede en EE. UU. al 1-800-654-8483 (opción 1) entre 7 y 20 h, Hora del Centro, o a través
de nuestro sitio de internet www.byjasco.com.
Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW4002
Power: 120VAC, 60Hz | Signal (frequency): 908.4/916MHz
Maximum loads: 2.5A no more than two identical fans to the switch. Not to exceed 2.5A resistive
load. CONTROLS FAN MOTOR ONLY. For use only with split-capacitor or shaded-pole ceiling
fan motors.
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver
module
Operating temperature range: 32-104° F (0-40° C)
For indoor use only
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4002
Tension : 120VCA, 60Hz | Signal (fréquence): 908.4/916MHz
Charges maximales : 2.5A pas plus de deux ventilateurs identiques pour l'interrupteur. La
charge résistive ne doit pas dépasser 2.5A. COMMANDES DU MOTEUR DU VENTILATEUR
UNIQUEMENT. À utiliser uniquement avec un condensateur auxiliaire ou des moteurs à bague
de déphasage pour ventilateurs.
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus
proche allant jusqu'à 150 pi (45.7m)
Plage de températures de fonctionnement : De 32° à 104° F (de 0 à 40° C)
Utilisation intérieure uniquement
En raison d'améliorations continues du produit, les spécifications peuvent faire l'objet de
changements sans préavis
ESPECIFICACIONES
ZW4002
Alimentación: 120VCA, 60Hz | Señal (frecuencia): 908.4/916MHz
Cargas máximas: 2.5A No más de dos ventiladores idénticos por interruptor. No deberá superar
2.5A de carga resistiva. CONTROLA SOLAMENTE EL MOTOR DEL VENTILADOR. Para uso
exclusivo con ventiladores de cielo raso que usen motores con condensador auxiliar o de polos
sombreados.
Alcance: Hasta 150 pies (45.7m) en línea recta entre el controlador inalámbrico y el módulo
receptor Z-Wave más cercano
Rango de temperatura de funcionamiento: 32°-104°F (0-40°C)
Para uso en espacios interiores solamente
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
Out to Light (Load)
B
A
D
E
C
From Breaker Box
Manual control
1. To turn the connected fan ON, press and release the top of the rocker.
Fan will return to last speed setting of the fan control – default = HIGH.
NOTE:
2. To turn the connected fan OFF, press and release the bottom of the rocker.
Adjust fan speed
The LED indicator confirms fan speed settings by flashing patterns:
LOW – LED will blink every two seconds for 10 seconds
MEDIUM – LED will blink every second for 10 seconds
HIGH – LED will blink every half second for 10 seconds
1. To increase fan speed, press and hold upper rocker.
2. To decrease fan speed, press and hold lower rocker.
The smart device only controls the fan motor and does not control any lighting connected
NOTE:
to the fan. If your fan has an integrated light, a second switch needs to be installed to control the
lighting directly. No more than two identical fans should be connected to the fan control. The total
load of the fan(s) should not exceed 2.5A.
To change color of the paddle
This step is optional. Before installation, you may want to change the
color of the paddle to match your wallplate or décor.
1. Lift the air gap tab at the base of the paddle.
2. Push the side tabs in on one side and then the other to release
paddle. Lift the cover up and of.
3. Simply put the new paddle onto the fan control by inserting the air
gap and side tabs and snapping securely into place.
Once this step is complete, return to section 3.
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave
network with other Z-Wave certified devices from other
manufacturers and/or other applications. All non-battery
operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Switch Multilevel Report and Central Scene Notification
• Association Group 2 supports Basic Set and is controlled by pressing the ON or OFF button
with the local load
• Association Group 3 supports Basic Set and is controlled by double pressing the ON or OFF button
• Each Association Group supports 5 total nodes
2.
1.

Publicidad

loading

Resumen de contenidos para Jasco ZW4002

  • Página 1 • Turn ON/OFF and adjust fan speed levels manually or remotely via the Z-Wave controller • Can be included in multiple groups and scenes • May be used in single-pole installation or with up to two Jasco add-on switches in 3-way or 4-way wiring configurations From Breaker Box •...
  • Página 2 • Peut être inclus dans de nombreux groupes et de nombreuses scènes. • Peut être utilisé en installation unipolaire ou avec un ou deux interrupteurs supplémentaires Jasco dans des configurations de câblage à trois ou quatre voies. • Palette d’interrupteur interchangeable – livré avec une palette blanche et une palette De la boîte des disjoncteurs...

Este manual también es adecuado para:

55259