Warranty - T.I.P. TFP 5000 UV 9 Instrucciones Para El Manejo

Estanque de fi ltro de presión
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
6.5.
Cleaning of the pump
Regular maintenance is recommended, at the latest when the water flow decreases (the following numbers
refer to Fig. 7)
• Disconnect the pump from the mains supply!
• Ensure that the filter cap of the pump is not clogged by leaves and dirt deposits; clean it if necessary.
• Press the sides of the front cover (2) and pull it off of the pump.
• Pull the filter sponge out of the filter cover.
• Turn the inflow cover (4) anticlockwise approx. 90°.
• Make sure that the O-ring (10) is in the recess provided.
• Clean the rotor (8) and motor housing (11) under tap water, remove incrustations and check for wear by
holding the shaft and rotating the rotor: the rotation must be regular.
• Reassemble the whole thing in the reverse order and attach the various components correctly.
• The pump should be cleaned and kept dry at the end of the season as described in this section.
Winter - maintenance
Protect your external pond filter from freezing!
If there is danger of freezing, take the pump out of your garden pond.
Completely clean the pump as specified in the instructions.
Store the pump over winter in a frost-free location.

7. Warranty

The present device was manufactured and inspected according to the latest methods. The seller warrants for
faultless material and workmanship in accordance with the legal regulations of the country in which the
device was purchased. The warranty period begins with the day of the purchase and is subject to the
provisions below:
Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing
will be eliminated free of charge. Any complaints are to be reported immediately upon their detection.
The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third
parties. Damage resulting from improper handling or operation, incorrect setting-up or storage, inappropriate
connection or installation or Acts of God or other external influences are excluded from warranty.
Parts subject to wear, such as the UV–C tube, rotor and bearings are excepted from the guarantee. All parts
were manufactured using maximum care and high-quality materials and are designed for a long lifecycle. It
should be understood, however, that the wear and tear depends on the kind of use, the intensity of use and
the internals of maintenance. Complying with the installation and maintenance information contained in the
present operating instructions will therefore considerably contribute to a long lifecycle of these wearing parts.
In case of complaints, we reserve the option of repairing or replacing the defective parts or replace the entire
device. Replaced parts will pass into our property.
Claims for liquidated damages are excluded unless they are caused by willful acts or negligence on the side
of the manufacturer.
The warranty does not provide for any claims beyond those referred to above. The warranty claim has to be
evidenced by the purchaser in the form of the submission of the sales receipt. The present warranty
commitment is valid in the country in which the device was purchased.
18
8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tfp 10000 uv 11Tfp 15000 uv 13

Tabla de contenido