Program Parameter Map
To momentarily
Supply
view Set-points
on
press
Timing starts
or
from 0 or nnnn
To change Set-point,
momentarily press
PRG
Displays
SEt 1
SEL
Press
Displays value
with lsd (right)
digit flashing
Press
or
until correct value,
SEL
then press
Displays value
with next digit
flashing
Repeat previous
step for next two
PRG
digits, then press
For single
For dual Timer
Timer options
options
Displays
SEt 2
Repeat as
for SEt1
Times out to
value of SEt 1
& OP 1 led on
RST
Press
or switch
supply off then on.
Timing starts
from 0 or nnnn
Note : These routines apply to
programming from default values.
Once another set-up has been
programmed, parameters will
start from the previous settings.
To change other
Program parameters
for SEt 1
press & hold
Displays
for > 4 secs.
PASS
for SEt 2
SEL
Press
Displays
0000
with msd (left)
digit flashing
Press
or
SEL
then press
Repeat until code 3232,
PRG
then press
Displays
nodE
Press
SEL
Press
PRG
Displays
dE-1
Press
or
until required mode,
PRG
then press
For all modes
except 24H
Displays
r nG1
Press
SEL
Press
PRG
Displays
SECS
Press
or
until required range,
PRG
then press
For dual Timer
options
Displays
r nG2
Press
Repeat as
PRG
for rnG1
Displays
cnt
Press
SEL
PRG
Press
Displays
uP
Press
or
to toggle between 'up'
& 'dn', then press
Displays
rSEt
Press
SEL
PRG
Press
Displays
OFF
Press
or
to select menu item
required, then
PRG
press
Displays
ASt
Press
SEL
Press
PRG
Displays
On
Press
or
to toggle between 'on'
& 'off', then press
Displays
bEEP
Press
Press SEL
PRG
Displays
OFF
Press
or
to toggle between 'on'
& 'off', then press
To set 24Hr times,
when selected
PRG
PRG
press
Displays
CLOC
Press
PRG
Press
Displays
00.00
with
msd (left)
.
digit flashing
Press
then press
Repeat until correct
time, then press
Displays
On-1
Press
PRG
SEL
Press
Displays
00.00
with
For 24H
msd (left)
mode
digit flashing
Press
then press
Repeat until correct
time, then press
Displays
OFF1
Press
PRG
Press
For
Displays
single
00.00
with
Timer
msd (left)
options
digit flashing
Press
then press
Repeat until correct
time, then press
Repeat sequence
for
On-2
and
OFF2
PRG
Displays
butt
Press
PRG
Press
Displays
On
Press
to toggle between 'on'
& 'off', then press
Displays
PASS
Press
PRG
Press
Displays
3232
with msd (left)
digit flashing
PRG
Press
then press
Repeat until required,
code then press
Displays
End
Switch supply off, then
PRG
on, to start timing.
To momentarily
view 24H mode
PRG
on-1 & off 1
settings press
and hold
Alternately
SEL
displays
on-1 & off 1
times for 2 sec
Repeat above
for on-2 & off 2
or
settings using
SEL
.
button
PRG
Alternately
displays
on-2 & off 2
times for 2 sec
or
SEL
.
PRG
SEL
or
SEL
.
PRG
Displays time
Press
of day and
PRG
continues timing
SEL
or
PRG
SEL
or
SEL
.
PRG
REF : Q03301 ISSUE 2