Technical Characteristics - LME RT-WP Guia De Inicio Rapido

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USER GUIDE
RT-WP
USER GUIDE
F
EATURES
7 days program
( except for daily version)
9 Built-in programs
4 User programs
Program graphic display
Room temperature and Time display
Comfort / Reduced / Anti-freeze
temperatures
Temporary temperature override
Automatic or Manual operation
Holiday function
T
ECHNICAL CHARACTERISTICS
Measured temperature
0.1°C (or 0.2°F)
precision
Set temperature precision
0.5°C (or 0.5°F)
in comfort & reduced : 5°C - 35°C (or 41°F - 95°F)
Set temperature range
in anti-freeze : 0,5°C - 10°C (or 33°F -50°F)
- regulation speed: 7.5 cycle per hour
Regulation
(8 minutes cycle)
characteristics
- regulation band: 2°K of proportional band
(adjusted power)
Driving element
8A 250VAC RELAY
Connection
3 points screw connector on the rear part of the box
3x LR6 AA 1.5V Alkaline batteries
Batteries
IMPORTANT: You have 1 minute to change the batteries
The RT-WP Chrono-thermostat is a
programmable digital thermostat able to
control and regulate directly your central
heating (Electric, Gas, Oil) or cooling
system. It's weekly programmable function
enables power savings according to your
every day life.
Select HOT or COLD operation
Easy wiring (2 conductor wire)
Keypad lock function (child safety)
Battery powered to prevent loss of
program
and time during power cuts
Battery weakness monitoring
Battery replacement without loss of
program
Reset function
GB
D
I
IMENSIONS
NSTALLATION
60mm
125mm
1
Place the RT-WP thermostat (A) on a
plain wall away from windows and doors and
not to close to the heater.
Put the connection wires (B) thru the back hole
of the rear part. Use the screws (C) to mount
the rear part on the wall.
2
Connect the wires to the connector
(D). Follow the connection diagram
3
Remove the plastic isolator on the
batteries to power up the RT-WP. Then close
the RT-WP
4
Adjust the time and follow the Q
S
instructions
TART
INSTRUCTIONS
Holiday function activated
Temperature overridden
Central heating working
Temperature
use + / - keys
to change temperature
Room temperature displayed
& W
IRING
2
1
34mm
L
UICK
N
Operating mode MENU
NO Actuator
NC Actuator
use
keys
to change mode
Weak Batteries
Week days
Time display
Graphic program display