RAS addressing
The address of the reader for BUS operations is set to the
default address RAS 16. Using a configuration card or
accessing its on-line Menu system when connected to the
RS485 BUS can change this. See the Programming Guide,
Reader Address, for further details.
Tamper
The reader is provided with a Tamper facility. When connected
to the BUS, Tamper data is transmitted to the Advisor Master
with system data. An external Open Collector output (violet
wire) can be configured as a Tamper control for both online
and offline operation.
Reader wiring
Red
Positive 9 to 14 VDC supply
Black
0 Volts
DC supply ground
RS485 Data − Wiegand Data 0
Green
D0/D− Clock
Absolute maximum, 12 V @ 10 mA
White
D1/D+ Data
RS485 Data + Wiegand Data 1
Absolute maximum, 12 V @ 10 mA
Offline LED control configured to "Two Wire
Brown
LED 1
Control" will control the red LED only
Wire grounded: Red LED on
Wire open: Red LED off
Wire at +5 V to +12 V: Red LED off or, offline
LED control configured to "One Wire Control"
will control both the red and blue LED's
Wire grounded: Blue LED on
Wire open circuit: Both LED's off
Wire at + 5 V to 12 V: Red LED on
Absolute maximum, 14 V
Yellow LED 2
Configurable to control the blue LED when
offline
Wire grounded: Blue LED on
Wire open: Blue LED off
Wire at +5 V to +12 V: Blue LED off
Request to exit input when online to Advisor
Master
This input may be connected to a simple push
button connected to Ground with RTE Only
selected on the option card or in Menu 10
(See Programming Guide for more details).
Blue
Buzzer
Offline Buzzer control.
Wire open or +5 V to +12 V: Buzzer off
Wire grounded: Buzzer sounding
Absolute maximum, 14 V
Configurable as: Door relay, −Tamper output,
Violet
Open
Collector
Credit controlled Pulsed, Timed or Latched
output
Note:
not be used to directly energise high current
door openers.
Absolute maximum, 14 V @ 25 mA
2 / 20
This is a low current output and must
Specifications
Number of card combinations
Supply voltage
Current consumption
Wireless operating frequency
Maximum power output
Dimensions of housing
Operating temperature
Relative humidity
Protection class
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
EN 50131
EN 50131-1 System requirements
EN 50131-3 Control and indicating equipment
Security Grade 3, Environmental class II
Tested and certified by Telefication B.V.
UTC Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of all applicable rules
and regulations, including but not limited to the
Directive 2014/53/EU. For more information see:
www.utcfssecurityproducts.eu
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.utcfssecurityproducts.eu
P/N MAINST-ATS1190 • REV C • ISS 07FEB19
— 48 bit
12
28x10
9 to 14 V
25 mA
80 mA max.
119.0 to 128.6 kHz
65.70 dBµA/m at 10 m
ATS1190: 36 x 110 x 20 mm
ATS1192: 42 x 150 x 16 mm
−35 to +66°C
93%, noncondencing
IP54
or scan the QR code.