Factory Settings; Technical Specifications - Maddalena RadioEVO Instrucciones De Instalación

Módulo radio wm-bus para contadores de agua
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Fitting instructions
1. Detach the transparent cover from
the meter; if necessary, clean the
surface over the pointer.
3. Tighten the screw (provided with
the sealing kit). After the screw has
been tightened correctly, a red led
will blink during activation (radio
ON).
Activation of the module
The device is deactivated upon delivery (only the calendar is active). When the
installation procedure is complete, the module will activate automatically (radio
ON/all functions) according to the factory default settings. Allow a few revolutions
of the pointer before it starts counting (self-calibration).
2. Fit the sensor in its seat. If
necessary, write down the radio's ID
shown on the label (module) and
the meter's serial number.
4. Seal the screw with the tamper-
evident label provided. A
mechanical seal is available on
request (lid on request).
3

Factory settings

Radio transmission factory settings (custom settings excluded):
wM-Bus T1 mode (encryption disabled), short data frame
Transmission interval: every 2 minutes, 8:00 a.m. to 6:00 p.m.,
Monday to Friday, 12 months
Starting value: 0 litres
Billing dates:
1. Yearly on 31 December
2. Monthly at the end of each month
The configuration settings can be changed via radio with the dedicated software
available for download at www.maddalena.it (a radio transmitter and the key for
the configuration are needed).
The configuration settings can be changed within a limited period of time by
putting the key close to the radio module (left side).

Technical specifications

SENSOR
Inductive, dual spool (bidirectional)
COMPATIBLE METERS
CD SD PLUS EVO, VTZ and other meters of the Modularis series
SENSOR ACCURACY
1 litre
Tampering, magnetic fraud, backflow, suspected leak, meter
ALARMS
blocked, maximum flow rate, meter inverted
CONFIGURATION
Via radio
POWER SUPPLY
Lithium-ion battery (replaceable), 11 years + 1 year storage
CE in accordance with the European standards.
EMC: EN 610000-4-2, EN 610000-4-3, ETSI EN 301 489-1 v1.9.2,
APPROVALS
ETSI EN 301 489-3 v1.6.1,ETSI 300 220
ISO 4064 Ancillary device 6.3 (with CD SD PLUS EVO)
STANDARD
Wireless M-Bus, OMS
MODES
T1,C1
FREQUENCY
868 MHz
TRANSMISSION DISTANCE
500 m in line of sight
REFERENCE STANDARDS
EN 13757
Short frame: current volume, volume on the billing dates,
meter's serial number, alarms.
DATA TRANSMITTED
Long frame: same as the short frame and in addition the values
of the latest 12 months.
Storage temperature: -20 °C ÷ +60 °C
ENVIRONMENTAL CONDITIONS
Operating temperature: -10 °C ÷ +55 °C
PROTECTION RATING
IP67