ENGLISCH
ENG
immediately with plenty of water. If battery fluid
leaks out and comes into contact with your eyes,
wash them with clean water and seek medical
treatment immediately!
Do not recharge a fully charged battery pack!
Overcharging damages and shortens the lifespan
of the battery pack!
Only use the charger indoors.
Protect the charger from moisture.
Children should be supervised to ensure that they
do not play with the tool.
Keep children away from the battery charger and
the working area!
Keep your battery charger out of reach of children!
Pull out the mains plug immediately if the battery
charger starts to smoke or flames emerge!
Do not insert objects into the ventilation slots on
the battery charger - there is a danger of electric
shocks and short circuits!
Do not use faulty battery packs.
5 Overview
See page 3.
1 Charging compartment
2 Operating indicator
3 Warning display
6 Commissioning
Before plugging in, check to see that the
rated mains voltage and mains frequency,
as stated on the rating label, match with
your power supply.
Before commissioning the charger,
ensure that the air slots are free. Minimum
distance to other objects is 5 cm.
6.1
Self-test
Insert mains supply plug.
The warning display (3) and the operating indicator
(2) light up in succession for approx. 1 second.
8
7 Use
7.1
Charging battery pack
Insert battery pack up to the stop in the charging
compartment (1). If necessary, use an adapter for
the battery pack (available as accessory).
A battery pack that is new or has not been used for
some time only reaches full capacity after being
charged and discharged several times.
The operating indicator (2) flashes.
7.2
Conservation charge
Once the charging process has finished, the
battery charger automatically switches to
conservation mode.
The battery pack can remain in the battery charger
and is therefore always ready for use. However,
never leave the battery pack in a disconnected
battery charger because of the possibility of
exhaustive discharge and damage to the battery
cells.
The operating indicator (2) lights up continuously.
8 Fault
8.1
Warning display (3) lights up
continuously
Battery pack is not charged. Excessive/Insufficient
temperature. When the temperature of the battery
pack is between 0 °C and 50 °C, the charging
process begins automatically.
8.2
Warning display (3) flashes
• Battery pack is defective. Remove the battery
pack immediately from the charger.