TECHNICAL DATA
ROS 125 E
Rated input ....................................................................................................................................................................................300 W
No-load speed ...............................................................................................................................................................7000 - 12000 min
Orbital travel diameter............................................................................................................................................................2,4 mm ( 3/32")
Dimensions of grinding plate ........................................................................................................................................................ 125 mm
Weight according EPTA-Procedure 01/2003 .................................................................................................................................. 1,7 kg
Noise/Vibration Information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K=3dB(A)) ................................................................................................................................................. 81,0 dB (A)
Sound power level (K=3dB(A)) ....................................................................................................................................................92,0 dB (A)
Wear ear protectors!
Total vibration values (vector sum in the three axes) determined according to EN 60745.
Vibration emission value a
............................................................................................................................................................ 5,0 m/s
h
Uncertainty K= .............................................................................................................................................................................. 1,5 m/s
WARNING
The vibration emission level given in this information sheet has been
measured in accordance with a standardised test given in EN 60745
and may be used to compare one tool with another. It may be used
for a preliminary assessment of exposure.
The declared vibration emission level represents the main applica-
tions of the tool. However if the tool is used for di erent applications,
with di erent accessories or poorly maintained, the vibration
emission may di er. This may signi cantly increase the exposure level
over the total working period.
An estimation of the level of exposure to vibration should also take
into account the times when the tool is switched o or when it is
running but not actually doing the job. This may signi cantly reduce
the exposure level over the total working period.
Identify additional safety measures to protect the operator from the
e ects of vibration such as: maintain the tool and the accessories,
keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all instruc-
tions, including those given in the accompanying brochure.
Failure to follow the warnings and instructions may result in electric
shock, re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors. Exposure to noise can cause hearing loss.
Always wear goggles when using the machine. It is recommended to
wear gloves, sturdy non slipping shoes and apron.
The dust produced when using this tool may be harmful to health.
Do not inhale the dust. Use a dust absorption system and wear a
suitable dust protection mask. Remove deposited dust thoroughly,
e.g. with a vacuum cleaner.
Do not use machines on any material containing asbestos.
This machine is suitable only for dry sanding.
Appliances used at many di erent locations including open air should
be connected via a residual current device (FI, RCD, PRCD) of 30mA
or less.
Only plug-in when machine is switched o .
Before doing any work on the machine, pull the plug out of the
socket.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
SPECIFIED CONDITIONS OF USE
This eccentric sander is a versatile machine. The following work can
be carried out with it: Coarse sanding and grinding, Fine sanding
and polishing, Rubbing down weather-beaten paint, Rubbing down
weather-beaten paint, Polishing up scratches on acrylic glass, Etc.
Do not use this product in any other way as stated for normal use.
EC DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in confor-
mity with the following standards or standardized documents.
EN 60745-1:2009 + A11:2010
EN 60745-2-4:2009 + A11:2011
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
in accordance with the regulations 2011/65/EU (RoHS), 2006/42/EC,
2004/108/EC
Winnenden, 2012-09-05
Random Orbital Sander
-1
2
2
Rainer Kumpf
Director Product Development
Authorized to compile the technical le
English
7
GB
GB