Install the Fixture
1A
ELECTRICAL BOX
NEUTRAL WIRE
1
HOT WIRE
MAX
100
Use
120 volt
Watt
Type A19 Medium Base Lamp.
1
Secure the mounting plate to the electrical box with two mounting plate screws.
Connect the fixture to a suitable ground in accordance to local electrical codes.
2
3
Connect the white fixture wire to the neutral power line wire with a wire nut.
Connect the black fixture wire to the hot power line wire with a wire nut.
4
Align then place the fixture base onto the mounting plate studs and secure it with the two cap nuts.
5
6
Screw the lamp into the socket.
MOUNTING
PLATE STUD
WHITE WIRE
5
1
3
2
4
5
MOUNTING
PLATE
BLACK WIRE
FIXTURE BASE
CAP NUT
5
MOUNTING
PLATE SCREW
6
2
LAMP