3.4 Reset the Lock
Please note all data will be erased if you reset U-Bolt WiFi to
factory default. If you are using U-tec App as Owner, please click
"Delete and Reset" to remove the lock from your U-tec Account,
then use a Reset Needle to push the Reset Button (at the bottom
of Interior Assembly) for around 3 seconds until you hear one long
beep and two short beeps.
3.5 Replace Batteries
Please use 4 high-quality alkaline AA batteries for replacement
when the battery is dead.
3.6 Emergency Key Override
Emergency Key Override can be used when the battery is dead.
Important Note
Please keep at least one key in secure location outside of
your place.
3.7 Enable Or Disable Auto Lock
Enable
Please keep Bolt unlocked and press "1" button for 3 seconds until
LED turns green and "1" button blinks.
Disable
Please keep Bolt unlocked and press "0" button for 3 seconds
until LED turns green and "0" button blinks.
This can also be set in U-tec App and Auto Lock timing can be
programmed between 10 seconds to 5 minutes. Factory Default
timing is 30 seconds.
3.8 Anti-peep Keypad
The lock supports up to 16-digit Vague Code. Just enter any
16-digit code, as long as a correct code is included in what you
entered, you can open the door.
User Code: 123456
1:
2:
3:
Example
Vague Code
1 2 3 4 5 6
X X X X X X
1 2 3 4 5 6
X X X
- 14 -
X X X X X X
1 2 3 4 5 6
X X X