Care And Cleaning; Troubleshooting; Replacement Parts List - Glacier bay TL-7620HC-RW Guía De Uso Y Mantenimiento

Inodoro alargada todo en uno de alta eficiencia
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Care and Cleaning

Your new toilet is made of stain-, acid-, and abrasion resistant vitreous china. Clean the outside surface with mild soap, warm water and a
soft cloth. On stubborn stains use a powdered detergent and damp sponge or nylon scouring pad. Never use abrasive scouring powders,
cleansers or pads because they will scratch, damage and dull the surface. The manufacturer shall not be responsible or liable for any tank
tting damage caused by the use of cleaners containing chlorine (calcium hypochlorite). When cleaning your toilet seat, wash it with mild
soapy water. Rinse seat thoroughly with clean water and dry with a soft cloth. Avoid detergents, disinfectants or cleaning products in
aerosol cans. NEVER use abrasive scouring powders on your seat. Some bathroom chemicals and cosmetics may cause damage to the
seat's nish, so test your cleaning solution on an inconspicuous area before applying to the entire surface.
WARNING: DO NOT USE IN -TANK CLEANERS. Products containing chlorine (calcium hypochlorite) can seriously damage tank ttings
potentially causing leaks, excessive water use and property damage.

Troubleshooting

Problem
No water ows into the tank.
The ush quality of the toilet is
poor.
Water continues to run.

Replacement Parts List

Part Name
Fill Valve
Flush Valve
Make sure the water supply valve is fully open.
Check the debris lter screen for any obstruction that would restrict the water supply. To
check the debris screen, shut off the water supply. Disconnect the supply line. Remove any
debris from inside the threaded shank which might be preventing proper water ow.
Reconnect and turn the water supply on, checking for leaks.
Make sure the water level in the tank is up to the water line printed on the over ow tube of
the ush valve. To increase the water level, turn the adjustment screw on the ll valve
clockwise to raise the oat cup.
Check to make sure the rubber seal gasket on the ush valve is completely closed. Clear any
debris from the gasket surface and sealing area of the ush valve which may be obstructing
full closure.
400A
540A
8
Solution
Model Number

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Tl-7620hc-ew340-995686-826

Tabla de contenido