Descargar Imprimir esta página

Stanley STHT77616 Manual De Instrucciones página 13

Ocultar thumbs Ver también para STHT77616:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
On the keypad, make sure:
7.
is solid RED (Figure Ⓗ ①).
turns ON (Figure Ⓑ ②).
8.
Use the laser tool.
When you are finished using the laser tool in the Vertical
9.
Position, press
to turn the laser tool OFF.
Performing Accuracy Checks
NOTE:
• The laser tool is sealed and calibrated at the factory to the
Rotary Laser Specifications listed in this manual.
• It is recommended that you perform the accuracy checks
before using the laser tool.
• Be sure to allow the laser tool adequate time to Auto-Level (at
least 5 seconds) prior to performing an accuracy check.
• The laser tool should be checked regularly to ensure its
accuracy, especially for precise layouts.
Horizontal Check
Mount the laser tool in its horizontal position (Figure Ⓐ ①)
1.
on a tripod 5m from a wall, with the front of the laser tool
facing the wall (Figure Ⓝ ①).
Power ON the laser tool in Self-Levelling Mode
2.
(Figure Ⓜ ①).
Wait 5 seconds for the laser tool to Auto-Level and make
3.
sure the rotary laser beam is rotating.
Where the laser line appears on the wall, mark point D
4.
(Figure Ⓝ ①). If available, use a detector to more easily
locate the beam.
5.
Turn the laser tool 180° on the tripod. The back of the laser
tool should now be facing the wall (Figure Ⓝ ②).
Where the laser line appears on the wall, mark point D
6.
(Figure Ⓝ ②).
Measure the vertical distance between points D
7.
(Figure Ⓝ ③).
• If the distance between D
calibration is not required. You can continue using your
laser tool.
• If the distance between D
have your laser tool calibrated at an authorized Stanley
service center. To locate your nearest Stanley service
center, go to www.2helpU.com.
Turn the laser tool 90° so the left side faces the wall
8.
(Figure Ⓝ ④).
Repeat steps
9.
4.
Vertical Check
1.
Mount the laser tool in its vertical position (Figure Ⓐ ②) on
a level tripod 1m from a wall that is at least 2m high, with
the left side of the laser tool facing the wall (Figure Ⓞ ①).
Power ON the laser tool in Manual Mode (Figure Ⓜ ②).
2.
Where the rotary laser beam appears on the floor 1m from
3.
the wall, mark point A (Figure Ⓞ ①):
Where the rotary laser beam, the floor, and the wall all
4.
meet, mark point B.
5.
Where the rotary laser beam appears 2m up the wall, mark
point D
.
1
Turn the laser tool 180° on the tripod. The right side of the
6.
laser tool should now be facing the wall (Figure Ⓞ ②).
7.
Move the level tripod to align the rotary laser beam with
points A and B.
1
Where the laser beam appears on the wall 2m above the
8.
floor, mark point D
Measure the horizontal distance between points D
9.
(Figure Ⓞ ②).
• If the distance between D
2
calibration is not required. You can continue using your
laser tool.
• If the distance between D
have your laser tool calibrated at an authorized Stanley
service center. To locate your nearest Stanley service
center, go to www.2helpU.com.
and D
is < 2.0mm,
1
2
and D
is ≥ 2.0mm, you must
1
2
through
for the sides of the laser tool.
7.
(Figure Ⓞ ②).
2
and D
is < 1.2mm,
1
2
and D
is ≥ 1.2mm, you must
1
2
GB
and D
GB
1
2
and D
1
2
13

Publicidad

loading