2. Pump (A) inlet connection is designed for 1
in. NPT thread. You can connect to the inlet
with either 1 in. NPT PVC or garden hose. For
garden hose connections, thread adapter (B)
into the inlet. Seal connections with PVC-safe
sealant or thread sealant tape.
NOTE: Minimize length of pipe and number of
fittings.
NOTE: The inlet hose must be a reinforced
type when pumping from lakes, ponds, or small
streams. Regular garden hose will collapse and
lead to failure of pump (A). Inlet line should be
the same diameter as the discharge line, or
larger.
3. Attach garden hose to adapter (B) or connect
1 in. PVC pipe directly to pump (A) inlet. A foot
valve with strainer (not provided) should be
installed at the end of the discharge hose or
pipe to maintain prime during operation.
4. Seal all connections in the inlet hose with
PVC-safe sealant or thread sealant tape (not
provided). An air leak in the fittings, hose,
pipe, or connections will reduce pump (A)
performance and lead to pump failure.
2
Inlet with
1-in. NPT
PVC
A
3
Water source
4
A
6
B
Inlet with
adapter and
reinforced
garden hose
A
PVC pipe or
reinforced
A
hose
Inlet
Foot valve
Seal all
connections
Inlet