Maintenance and cleaning
Cleaning the unit
NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the func-
tion of the device and harm animals, plants and the environment.
Clean the unit only with clean water and a soft brush or sponge.
Replacing the membrane
• Only use original spare parts from PfG.
– The unit may be damaged by the use of spare parts from other manufacturers.
How to proceed:
D
1. Position the membrane key with the notches on the ring nut and unscrew the ring nut in a counter-clockwise direc-
tion.
2. Remove the membrane and O-ring, check for damage, clean and, if necessary, replace.
3. Reassemble the unit in the reverse order.
– Ensure that the O-ring is correctly positioned.
4. Reconnect to the power supply and check the function.
Storage/overwintering
If the ambient temperature falls outside the permissible ambient temperature range, it is necessary to remove the unit.
(→ Technical data)
• Store the unit in a dry and frost-free place.
Troubleshooting
Malfunction
LEDs are not lit
Illuminating power decreasing
No mist generated
Technical data
PondoFog RGB
Transformer
Connection voltage
Power frequency
Max. power consumption
Output voltage
Max. power output
Protection type
Length of power cable
Weight
Misting unit with
Connection voltage
LED
Power consumption
Protection type
Max. immersion depth
LED color space
Misting unit water consumption
Permissible water temperature
Connection cable length
Dimensions (Ø × H)
Weight
Cause
Power supply interrupted
Transformer defective
Bulb defective
Lamp glass soiled
Membrane worn
V AC
Hz
W
V AC
VA
m
kg
V AC
W
m
–
l/h
°C
m
mm
kg
Remedy
Check power supply
Replace transformer
Bulbs cannot be replaced. Dispose of bulbs.
Clean
Replace membrane
230-240
50
13
24
24
IP44
2
0.65
24
23
IP68
1
RGB
0.5
+4 ... +35
8
120 × 75
0.35
- EN -
9