Cross Tools CPG 3000 V Traducción De Las Instrucciones De Uso Originales página 28

Tabla de contenido

Publicidad

Risks and scope of prevention
4.7.
Risk
Direct electrical con-
tact
Burns
Hearing impairments
Contact, inhalation
Fire or explosion
Environmental haz-
ards
Breakage during oper-
ation
Generator circuit breaker
4.8.
The generator is equipped with a combined thermal / magnetic circuit breaker.This circuit
breaker allows higher currents to pass for a short period of time in order to allow 3-phase
motors to start up.If the load is higher than the permitted value for a longer period of time, the
circuit breaker disconnects the load from the generator.For this reason, check before first use
whether the load connected lies within the permissible range as the circuit breaker could dis-
connect the load from the network after a certain time in order to protect the generator from
overloading.
26
Description
Direct electrical contact with wet
hands can cause electrical
shocks.
Touching the exhaust can cause
burns.
Prolonged stay near a running
generator can cause hearing
impairments.
Inhaling exhaust fumes can be
fatal!
The fuel of the device can catch
fire.
Leaking of oil and fuel damages
the environment.
If the device is operated on a
sloping surface, lubrication is not
ensured and the device can be
damaged.
Translation of the original operating instructions
Prevention
Avoid contacting the device with
wet hands and make sure the de-
vice has appropriate grounding.
Let the devices cool down after op-
eration.
Always wear ear protection.
Never operate the device in closed
rooms.
Never operate in inflammable envi-
ronment. Never refuel when engine
is running. No smoking.
Avoid leakage of these substances
and use collecting trays during
maintenance.
Always operate on a flat surface.
7

Publicidad

Tabla de contenido
loading

Tabla de contenido