translated from italian
10
TECHNICAL FEATURES
10.1
TECHNICAL DATA
The use conditions and the characteristics of the environment where the equipment is located must
respect the technical data of the table.
MEASURING
ACCURACY CLASS
CLIMATIC ENVIRONMENT CLASS
ELECTROMAGNETIC ENVIRONMENT
CLASS
MECHANICAL ENVIRONMENT CLASS M1
PROTECTION
OUTPUT
PULSE WEIGHT
PULSES PER LITRE
MIN. MEASURED QUANTITY
MIN. FLOW RATE RANGE
MAX. FLOW RATE RANGE
MIN. FLUID PRESSURE
MAX. FLUID PRESSURE
VISCOSITY RANGE
FLUID TEMPERATURE
ENVIRONMENTAL TEMPERATURE
STORAGE TEMPERATURE
STORAGE HUMIDITY
ACCURACY
REPEATABILITY (Q.TY > 25 l)
SUPPLY
LOAD LOSS
WEIGHT
MATERIALS
DENSITY RANGE
USE PLACES
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
Volume
0.5
H1
E1
IP67
2 square waves, 90° offset
6.25 ml
160
5 l
5 l/min
35 l/min
0.1 bar
20 bar (maximum resistance at 140 bar)
1 mPa•s - 2,2 mPa•s
-10 °C - +40 °C
-10 °C - +40 °C
-20 °C - +60 °C
95 (% R.H.)
+/- 0.3%
≤ 0.2% (OIML R117-1 – A.6.1 – 3.1.2.2 - Table 2)
VOLTAGE 3,3V DC - 28V DC
CURRENT 0,6 mA
0.3 bar (at 35 l/min)
2.2 kg
Body: AISI304
Electronics compartment: Al AW6060 Gears: PEEK
Gear shafts: AISI304
0,9970 g/cm 3 - 1,104 g/cm 3
Protected from direct weather agents
MK325
31
31 /112
/124