MIT400 and MIT2500 series safety warnings
National Health and Safety Legislation requires users of this
assessments of all electrical work so as to identify potential sources of electrical danger and risk of electrical inJury such
as inadvertent short circuits.
Where the assessments show that the risk is significant then the use of
The
voltage indicator and automatic discharge features must be regarded as additional
substitute for normal safe working practice which MU5T be followed.
The circuit under test must be switched
are made when carrying out insulation and continuity tests.
Test voltages greater than
1
000V de
Circuit connections greater than 15
under test must not be touched during testing.
The Voltmeter function will operate
After
an
insulation test, the instrument must be
Do
not handle test leads above the 1000
The instrument should
not
be used if any part of
All test leads, probes and crocodile clips
test
the integrity of the
leads before making measurements. Only
this product.
Ensure that hands remain
behind
finger guards of
National Safety Authorities
may
recommend
systems
Fused Leads must be tested independently before use to ensure fuse integrity.
Replacement fuses must be of the correct type and rating. Failure to fit the correctly
hazard and may cause damage to the instrument in the event of an overload.
All covers must be
in
place whilst conducting tests.
If
this equipment
is
used
in
a manner not specified
may be impaired
The instrument must be used only
by
Safety symbols marked on the instrument
/!\
Refer to user instructions
Lh
Risk
of electric shock
600V ac rms maximum between
CATN600V
terminals, and between terminal
and earth
Enclosure is dust proof and
IP54
protected against waters-plashes
Fuse FF 500mA 1000V 30kA
Installation category definitions:
CAT
IV
-
Measurement Galegory
IV:
Equipment connected
between the origin of the low-voltage mains supply and the
distribution panel.
CAT
Ill
-
Measurement Galegory Ill: Equipment connected
between the distribution panel and the electriG31 outlets.
CAT
II
-
Measurement category II:
Equipment
between the electriG3I outlets and the user's
equlpmenl
4
MIT400/2 and MrT2500
equipment
and their employers to carry out valid
fused
off.
de-energized.
securely
isolated and proved dead before test connections
must not be used on capacitive circuits. Capacitive charges can be lethal.
nF.
exposed-conductive-parts
and
other metalwork of
only
if the instrument is switched on and working correctly.
left
connected until the circuit has been discharged
V
range.
(For use
in
dry conditions only).
it
is damaged.
must
be
in
good order, clean
and
with
"Megger"
probes/clips.
the
use of fused test leads when measuring voltage on high-energy
by
the manufacturer, the protection provided by the equipment
suitably trained
and
competent persons.
CE:
UK
CA
&
-
Measurement equipment may be safely connected to curuits at the
marlced ra�ng or
lower.
This instrument is manufactured
the
right
to change the specification or design without prior notice.
Megger is a registered trademark.
connected
risk
test leads may be
appropriate.
safety
features
and
not a
an
installation or equipment
to
a safe voltage.
no
broken or cracked
insulation. Verify
approved test leads must be used with
rated
fuse may result
in
a
safety
Equipment protected throughout
by Double Insulation
Equipment complies with current
EU directives.
Equipment complies with current
UKCA directives
N13117 Equipment complies with
n
current "C tick
requirements
Do not dispose of in the normal
waste
rtream.
in
the EU. The company reserves
www.megger.com
4/8

Publicidad

loading

Este manual también es adecuado para:

Mit2500