In the ON position, the gate is AUTOMATICALLY CLOSED following a set PAUSE time after it has
opened.
N° 5A-6A
SLOWING DOWN
The slowing down phase is the final part of the travel of the gate during which the motor rotates at a
lower speed in order to prevent it from stopping too suddenly. The duration of this phase depends
on the pulses read by the encoder during the memorizing operation.
DIP No. 5
OFF
MIN
ON
↕
OFF
MAX
ON
N° 7A-8A
DOOR DELAY (MEC2000)
The duration of the delay is always proportional to the pulses read by the encoder during the
memorizing operation.
DIP No. 7
OFF
MIN
ON
↕
OFF
MAX
ON
N° 9A-10A
ELECTRONIC TYPE CLUTCH
The MEC1000 / MEC2000 panel is fitted with an encoder that can control the effective speed of the
gate or the two gates independently in the case of swing gates.
The motor thereby becomes sensitive to any drops in speed that can be caused either by an obstacle
or the mechanical travel stop. This sensitivity can be adjusted to 4 levels with dipswitches 9A and
10A. Fitters should opt for an average maximum power level.
DIP No. 9
OFF
MIN
ON
↕
OFF
MAX
ON
N° 1B
ON enables 2 motors.
OFF enables just one motor.
NB: 1 motor activates the relays of both motors in parallel but only reads from the M1 motor encoder.
For use with 2-motor up-and-over doors.
When DIP 7A is OFF, the reversal stroke is enabled to prevent the motor from locking.
For use with sliding gates.
N° 2B
ON enables the courtesy light. OFF enables the electric lock. Output 13/14.
N° 3B
ON enables the pre-flashing function.
OFF disables the pre-flashing function.
N° 4B
ON enables all the memorizing functions.
OFF is the position at which it must stay when memorizing operations have terminated (normal
opening and closing operation).
DIP No. 6
%
OFF
4.68
OFF
12.5
ON
37.5
ON
50
DIP No. 8
% D.OP % D.CL
OFF
2.34
OFF
4.69
ON
9.38
ON
18.75
DIP No. 10
OFF
1 MINIMUM
OFF
2 AVERAGE MINIMUM
ON
3 AVERAGE MAXIMUM
ON
4 MAXIMUM
EXAMPLE with 100 pulses memorized:
95.32 pulses at normal speed, 4.68 pulses at reduced speed
87.5 pulses at normal seed, 12.5 pulses at reduced seed
62.5 pulses at normal speed, 37.5 pulses at reduced speed
50 pulses at normal speed, 50 pulses at reduced speed
EXAMPLE with 100 pulses memorized:
4.69
2.34 delay open pulses, 4.69 delay close pulses
9.38
4.69 delay open pulses, 9.38 delay close pulses
18.75
9.38 delay open pulses, 18.75 delay close pulses
37.5
18.75 delay open pulses, 37.5 delay close pulses
POWER LEVEL
DIPSWITCH "B"
4 levels.
4 levels.
4 levels.